Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Rotary Switch
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
11.673 inches
MRC:
A measurement of the longest straight line across a circular cross-sectional plane.ADAV
Overall Diameter:
1.875 inches
MRC:
The number of individual sections included in the item.AFBH
Individual Section Quantity:
12
MRC:
The general configuration of the contacts of a switch that describes its basic switching structure.AJZE
Switch Contact Basic Design:
Nonpile-up symmetrical and nonpile-up nonsymmetrical
MRC:
The number of poles included in the item.AKPX
Pole Quantity:
1 12th section rear
MRC:
The number of poles included in the item.AKPX
Pole Quantity:
1 1st section front
MRC:
The number of poles included in the item.AKPX
Pole Quantity:
1 2nd section front
MRC:
The number of poles included in the item.AKPX
Pole Quantity:
1 10th section rear
MRC:
The number of poles included in the item.AKPX
Pole Quantity:
1 11th section front
MRC:
The number of poles included in the item.AKPX
Pole Quantity:
1 11th section rear
MRC:
The number of poles included in the item.AKPX
Pole Quantity:
1 8th section front
MRC:
The number of poles included in the item.AKPX
Pole Quantity:
1 8th section rear
MRC:
The number of poles included in the item.AKPX
Pole Quantity:
1 9th section front
MRC:
The number of poles included in the item.AKPX
Pole Quantity:
1 2nd section rear
MRC:
The number of poles included in the item.AKPX
Pole Quantity:
1 3rd section front
MRC:
The number of poles included in the item.AKPX
Pole Quantity:
1 3rd section rear
MRC:
The number of poles included in the item.AKPX
Pole Quantity:
1 4th section front
MRC:
The number of poles included in the item.AKPX
Pole Quantity:
1 4th section rear
MRC:
The number of poles included in the item.AKPX
Pole Quantity:
1 5th section front
MRC:
The number of poles included in the item.AKPX
Pole Quantity:
1 5th section rear
MRC:
The number of poles included in the item.AKPX
Pole Quantity:
1 6th section front
MRC:
The number of poles included in the item.AKPX
Pole Quantity:
2 10th section front
MRC:
The number of positions to which the item may be actuated to energize electrical circuits.AKPY
Throw Quantity:
1 6th section front
MRC:
The number of positions to which the item may be actuated to energize electrical circuits.AKPY
Throw Quantity:
1 3rd section rear
MRC:
The number of positions to which the item may be actuated to energize electrical circuits.AKPY
Throw Quantity:
1 4th section front
MRC:
The number of positions to which the item may be actuated to energize electrical circuits.AKPY
Throw Quantity:
11 1st section front
MRC:
The number of positions to which the item may be actuated to energize electrical circuits.AKPY
Throw Quantity:
10 12th section rear
MRC:
The number of positions to which the item may be actuated to energize electrical circuits.AKPY
Throw Quantity:
2 2nd section rear
MRC:
The number of positions to which the item may be actuated to energize electrical circuits.AKPY
Throw Quantity:
2 3rd section front
MRC:
The number of positions to which the item may be actuated to energize electrical circuits.AKPY
Throw Quantity:
2 5th section rear
MRC:
The number of positions to which the item may be actuated to energize electrical circuits.AKPY
Throw Quantity:
2 6th section rear
MRC:
The number of positions to which the item may be actuated to energize electrical circuits.AKPY
Throw Quantity:
2 8th section front
MRC:
The number of positions to which the item may be actuated to energize electrical circuits.AKPY
Throw Quantity:
2 10th section rear
MRC:
The number of positions to which the item may be actuated to energize electrical circuits.AKPY
Throw Quantity:
2 11th section front
MRC:
The number of positions to which the item may be actuated to energize electrical circuits.AKPY
Throw Quantity:
2 11th section rear
MRC:
The number of positions to which the item may be actuated to energize electrical circuits.AKPY
Throw Quantity:
3 9th section front
MRC:
The number of positions to which the item may be actuated to energize electrical circuits.AKPY
Throw Quantity:
3 10th section front
MRC:
The number of positions to which the item may be actuated to energize electrical circuits.AKPY
Throw Quantity:
6 9th section rear
MRC:
Indicates the number of connections on a rotor segment that are front to rear surface connected.CQTH
Rotor Through Connection Quantity:
1 2nd section
MRC:
Indicates the number of connections on a rotor segment that are front to rear surface connected.CQTH
Rotor Through Connection Quantity:
1 5th section
MRC:
Indicates the number of connections on a rotor segment that are front to rear surface connected.CQTH
Rotor Through Connection Quantity:
1 6th section
MRC:
Indicates the number of connections on a rotor segment that are front to rear surface connected.CQTH
Rotor Through Connection Quantity:
1 9th section
MRC:
An indication of the switching action by the contacts of the item.CSHW
Contact Switching Action:
Breaks before makes 10th section front
MRC:
An indication of the switching action by the contacts of the item.CSHW
Contact Switching Action:
Breaks before makes 10th section rear
MRC:
An indication of the switching action by the contacts of the item.CSHW
Contact Switching Action:
Breaks before makes 11th section front
MRC:
An indication of the switching action by the contacts of the item.CSHW
Contact Switching Action:
Breaks before makes 11th section rear
MRC:
An indication of the switching action by the contacts of the item.CSHW
Contact Switching Action:
Breaks before makes 12th section rear
MRC:
An indication of the switching action by the contacts of the item.CSHW
Contact Switching Action:
Breaks before makes 1st section front
MRC:
An indication of the switching action by the contacts of the item.CSHW
Contact Switching Action:
Breaks before makes 3rd section front
MRC:
An indication of the switching action by the contacts of the item.CSHW
Contact Switching Action:
Breaks before makes 3rd section rear
MRC:
An indication of the switching action by the contacts of the item.CSHW
Contact Switching Action:
Breaks before makes 4th section front
MRC:
An indication of the switching action by the contacts of the item.CSHW
Contact Switching Action:
Breaks before makes 5th section rear
MRC:
An indication of the switching action by the contacts of the item.CSHW
Contact Switching Action:
Breaks before makes 6th section front
MRC:
An indication of the switching action by the contacts of the item.CSHW
Contact Switching Action:
Breaks before makes 2nd section rear
MRC:
An indication of the switching action by the contacts of the item.CSHW
Contact Switching Action:
Breaks before makes 6th section rear
MRC:
An indication of the switching action by the contacts of the item.CSHW
Contact Switching Action:
Breaks before makes 8th section front
MRC:
An indication of the switching action by the contacts of the item.CSHW
Contact Switching Action:
Breaks before makes 9th section front
MRC:
An indication of the switching action by the contacts of the item.CSHW
Contact Switching Action:
Breaks before makes 9th section rear
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Circular wafer, bushing mount