Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Radio Frequency Transmiss Switch
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Rectangular
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
1.500 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
2.060 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
0.625 inches
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
0.0 megahertz single frequency operating and 450.0 megahertz single frequency operating
MRC:
Indicates the type of switch included in the item.AEEA
Switch Type:
Nontransfer
MRC:
The ratio of the maximum to the minimum amplitude of pressure /voltage/ measured along the path of the waves.AHTW
Voltage Standing Wave Ratio:
1.40 single
MRC:
The difference in the amount of energy available before and after the insertion of an apparatus in a transmission system,expressed in decibels.AHTX
Insertion Loss In Decibels:
0.60 single
MRC:
A letter or group of letters used to designate the particular coaxial connector series.AHUC
Coaxial Connector Series Designation:
Sma
MRC:
The design of the connector end.AHUD
Connector End Design:
Female
MRC:
The minimum amount of isolation the item offers against interference from adjacent channel operation,expressed in decibels.AKNV
Minimum Crosstalk Rating In Decibels:
50.0 single
MRC:
The means provided for switching the actuator from one position to another.AKPC
Actuator Operating Method:
Relay
MRC:
An indication of whether the lobe of the rotating cam is designed to actuate /make/ a switch before or after the preceding switch deactuates /breaks/.AKPN
Switch Operation Sequence:
Breaks before makes
MRC:
The time required for switching between any two adjacent positions.AKPP
Switching Time:
5.0 milliseconds
MRC:
The operation of the switch mechanism when the switch return actuator power is removed.AKPQ
Switch Return Mechanism Type:
Latching
MRC:
The number of poles included in the item.AKPX
Pole Quantity:
1
MRC:
The number of positions to which the item may be actuated to energize electrical circuits.AKPY
Throw Quantity:
2
MRC:
The number of coupling positions provided.AKRC
Coupling Position Quantity:
3
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
3 tab, solder lug and 3 receptacle, coaxial