Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Power Supply
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
12.000 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
5.000 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
8.000 inches
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
An/usc-3 (v) satcom terminals
MRC:
The commercial and government entity (cage) code of the government agency,industrial organization,or other source,which controls the document.AJJY
Document Source:
08742
MRC:
The relationship of the electrical power source to the item.AKWC
Electrical Power Source Relationship:
Operating
MRC:
The number of input alternating current phase(s).ANPM
Input Phase:
Single single operating power rqmt
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
115.0 ac pounds per hour wet single operating power rqmt
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
15.0 dc volts 2nd power output
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
15.0 dc volts 3rd power output
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
28.0 dc volts 4th power output
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
5.0 dc volts 1st power output
MRC:
The number of complete cyclic changes,per unit of time,for which the input is rated.APTQ
Input Frequency Rating:
47.0 hertz single operating power rqmt and 63.0 hertz single operating power rqmt
MRC:
The ambient temperature range at which the item is designed to operate.AYNH
Operating Ambient Tempurature Range:
+0.1/+71.0 degrees celsius
MRC:
The number of output control(s) provided.BGHX
Output Control Quantity:
1 1st power output
MRC:
The number of output control(s) provided.BGHX
Output Control Quantity:
1 2nd power output
MRC:
The number of output control(s) provided.BGHX
Output Control Quantity:
1 3rd power output
MRC:
The number of output control(s) provided.BGHX
Output Control Quantity:
1 4th power output
MRC:
Indicates the type of output control provided.BGHY
Output Control Type:
Voltage adjustment 2nd power output
MRC:
Indicates the type of output control provided.BGHY
Output Control Type:
Voltage adjustment 3rd power output
MRC:
Indicates the type of output control provided.BGHY
Output Control Type:
Voltage adjustment 1st power output
MRC:
Indicates the type of output control provided.BGHY
Output Control Type:
Voltage adjustment 4th power output
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
1.0 dc amperes 4th power output
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
12.0 dc amperes 3rd power output
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
12.0 dc amperes 2nd power output
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
120.0 dc amperes 1st power output
MRC:
The maximum alternating current voltage variation which may be present on the direct current output voltage level.CWGZ
Ripple Voltage At Full Load:
10.0 millivolts rms 1st power output
MRC:
The maximum alternating current voltage variation which may be present on the direct current output voltage level.CWGZ
Ripple Voltage At Full Load:
20.0 millivolts rms 2nd power output
MRC:
The maximum alternating current voltage variation which may be present on the direct current output voltage level.CWGZ
Ripple Voltage At Full Load:
20.0 millivolts rms 3rd power output
MRC:
The maximum alternating current voltage variation which may be present on the direct current output voltage level.CWGZ
Ripple Voltage At Full Load:
20.0 millivolts rms 4th power output
MRC:
Indicates the location of the output control(s).CWHC
Output Control Location:
Front panel 1st power output
MRC:
Indicates the location of the output control(s).CWHC
Output Control Location:
Front panel 2nd power output
MRC:
Indicates the location of the output control(s).CWHC
Output Control Location:
Front panel 3rd power output
MRC:
Indicates the location of the output control(s).CWHC
Output Control Location:
Front panel 4th power output
MRC:
The number of electrical output connections on the item.CWHF
Output Connection Quantity:
1 1st power output
MRC:
The number of electrical output connections on the item.CWHF
Output Connection Quantity:
1 2nd power output
MRC:
The number of electrical output connections on the item.CWHF
Output Connection Quantity:
1 3rd power output
MRC:
The number of electrical output connections on the item.CWHF
Output Connection Quantity:
1 4th power output
MRC:
Indicates the type of electrical output connection.CWHJ
Output Connection Type:
Receptacle, electrical 1st power output
MRC:
Indicates the type of electrical output connection.CWHJ
Output Connection Type:
Receptacle, electrical 2nd power output
MRC:
Indicates the type of electrical output connection.CWHJ
Output Connection Type:
Receptacle, electrical 3rd power output
MRC:
Indicates the type of electrical output connection.CWHJ
Output Connection Type:
Receptacle, electrical 4th power output
MRC:
The number of electrical input connections on the item.CWHT
Input Connection Quantity:
3 single operating power rqmt
MRC:
Indicates the type of design provided for ventilation of the item.CWKG
Ventilation Design Type:
Air cooled