Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
					
					
						Entmilitarisierung:
						Yes - DEMIL/MLI					 
					
					
					
				 
			 
							
					
						Informationen zum Teil
						Module,  power amplifier
					 
				 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Standardized Electronic Module				
			 
			
							
										
					
						MRC:
						The maximum force at impact that the item is rated to withstand,without resulting in any permanent change in physical or electrical characteristics,expressed in gravitational units /g's/.AFDP
					 
					
						Shock Resistance Rating In Gravitational Units:
					
					
						50.0					
				 
							
					
						MRC:
						The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
					 
					
						Operating Tempurature Range:
					
					
						+0.0/+60.0 degrees celsius					
				 
							
					
						MRC:
						The numeric value of the life expectancy of the item.AFHH
					 
					
						Average Life Rating:
					
					
						30000.0					
				 
							
					
						MRC:
						A term used to denote the specific measurement of duration used to indicate the average life of the item.AFSU
					 
					
						Average Life Measurement:
					
					
						Hours					
				 
							
					
						MRC:
						The national stock number or the identification information of the end equipment for which the item is a part.AGAV
					 
					
						End Application:
					
					
						Nato seasparrow surface missile system					
				 
							
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the basic appearance of the item.AGTA
					 
					
						Basic Shape Style:
					
					
						Irregular					
				 
							
					
						MRC:
						The maximum altitude at which the item is rated to function.AKAE
					 
					
						Maximum Operating Altitude Rating:
					
					
						8000.0 feet					
				 
							
					
						MRC:
						Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
					 
					
						Inclosure Type:
					
					
						Hermetically sealed					
				 
							
					
						MRC:
						The installation for which the item is designed.AMQY
					 
					
						Installation Design:
					
					
						Module					
				 
							
					
						MRC:
						Indicates the type of circuit construction provided in the item.BHSX
					 
					
						Circuit Construction Type:
					
					
						Solid state					
				 
							
					
						MRC:
						The portion of the frequency spectrum at which an item is designed to receive or transmit signal power.BHTB
					 
					
						Frequency Per Channel:
					
					
						Not rated					
				 
							
					
						MRC:
						The decrease in strength of an electrical impulse,expressed in decibels.BHTH
					 
					
						Attenuation In Decibels:
					
					
						Not rated					
				 
							
					
						MRC:
						The rated average power for each channel.BHTJ
					 
					
						Average Power Rating Per Channel:
					
					
						Not rated					
				 
							
					
						MRC:
						The rated signal voltage for each channel.BHTK
					 
					
						Signal Voltage Rating Per Channel:
					
					
						Not rated					
				 
							
					
						MRC:
						The increase in energy from the input to the output.BHTL
					 
					
						Overall Gain:
					
					
						Not rated					
				 
							
					
						MRC:
						The total opposition (resistive and reactive) to the flow of alternating current per channel.BHTN
					 
					
						Impedance Rating Per Channel:
					
					
						Not rated					
				 
							
					
						MRC:
						The maximum absolute peak value of the pulse per channel.BHTW
					 
					
						Pulse Peak Amplitude Per Channel:
					
					
						Not rated					
				 
							
					
						MRC:
						The length of time after impact that established the condition at which the shock resistance rating applies.BJBN
					 
					
						Shock Pulse Duration Time:
					
					
						11.0 milliseconds					
				 
							
					
						MRC:
						The value(s) of the potential supplied from an exterior direct current source to operate the item,expressed in volts.BKFB
					 
					
						External Dc Operating Voltage In Volts:
					
					
						0.0  2nd voltage err-100 and 0.25  2nd voltage err-100					
				 
							
					
						MRC:
						The value(s) of the potential supplied from an exterior direct current source to operate the item,expressed in volts.BKFB
					 
					
						External Dc Operating Voltage In Volts:
					
					
						0.25  1st voltage err-100 and 7.6  1st voltage err-100					
				 
							
					
						MRC:
						Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
					 
					
						Special Features:
					
					
						Warning,  this part contains beryllium oxide