Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Maßeinheit:
* special requirements. EA
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Pulse Transformer
MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Not established
MRC:
The value(s) of inductance inherent in the item.ACYV
Inductance Rating:
150.00 millihenries single component all secondary
MRC:
The value(s) of inductance inherent in the item.ACYV
Inductance Rating:
6.00 millihenries single component single primary
MRC:
The total opposition /resistive and reactive/ which the item offers to the flow of an alternating current,expressed in ohms.ACYW
Impedance Rating In Ohms:
15.0 single component single primary
MRC:
The total opposition /resistive and reactive/ which the item offers to the flow of an alternating current,expressed in ohms.ACYW
Impedance Rating In Ohms:
800.0 single component all secondary
MRC:
The ratio of the number of turns in a primary winding to the number of turns in the secondary winding of a transformer.ACZH
Primary To Secondary Turn Ratio:
1 to 7-19/64 to 7-19/64 single component
MRC:
The average rate at which the pulses recur within a specified time interval.ACZN
Pulse Repetition Rate:
1.5 kilohertz single component
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
7.500 inches
MRC:
A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
Body Width:
7.094 inches
MRC:
A measurement from the bottom to the top of the body,in distinction from depth.ADAU
Body Height:
7.594 inches
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Hermetically sealed
MRC:
The means of attaching the item.AXGY
Mounting Method:
Bracket single group and unthreaded hole single group
MRC:
The purpose and the total number of individual (not electrically connected) windings designed to perform in a transformer.BPLC
Winding Function And Quantity:
1 primary single component and 2 secondary single component