Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
					
					
						Entmilitarisierung:
						Yes - DEMIL/MLI					 
					
					
					
				 
			 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Radio Frequency Interfere Filter				
			 
			
							
										
					
						MRC:
						The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
					 
					
						Overall Length:
					
					
						Between 5.970 inches and 6.030 inches 					
				 
							
					
						MRC:
						An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
					 
					
						Overall Width:
					
					
						Between 3.970 inches and 4.030 inches 					
				 
							
					
						MRC:
						A measurement of the longest dimension of the body,in distinction from width.ADAQ
					 
					
						Body Length:
					
					
						Between 4.970 inches and 5.030 inches 					
				 
							
					
						MRC:
						A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
					 
					
						Body Width:
					
					
						Between 2.970 inches and 3.030 inches 					
				 
							
					
						MRC:
						A measurement from the bottom to the top of the body,in distinction from depth.ADAU
					 
					
						Body Height:
					
					
						Between 2.970 inches and 3.030 inches 					
				 
							
					
						MRC:
						The length of a straight line which passes through the center of an unthreaded mounting hole,and terminates at the circumference.AEBV
					 
					
						Unthreaded Mounting Hole Diameter:
					
					
						Between 0.183 inches and 0.203 inches 					
				 
							
					
						MRC:
						The distance between centerlines of mounting facilities parallel to the length of the item.AEBY
					 
					
						Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
					
					
						Between 5.490 inches and 5.510 inches 					
				 
							
					
						MRC:
						The distance between centerlines of mounting facilities parallel to the width of the item.AEHA
					 
					
						Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
					
					
						Between 3.490 inches and 3.510 inches 					
				 
							
					
						MRC:
						The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
					 
					
						Operating Tempurature Range:
					
					
						+0.0/+50.0 degrees celsius					
				 
							
					
						MRC:
						The national stock number or the identification information of the end equipment for which the item is a part.AGAV
					 
					
						End Application:
					
					
						An/bqr-15receiving set, sonar					
				 
							
					
						MRC:
						The cycles per second /hertz/ of the power line alternating current.AHBB
					 
					
						Power Line Frequency Rating Per Function In Hertz:
					
					
						60.0 1st radio interference					
				 
							
					
						MRC:
						The cycles per second /hertz/ of the power line alternating current.AHBB
					 
					
						Power Line Frequency Rating Per Function In Hertz:
					
					
						60.0 2nd radio interference					
				 
							
					
						MRC:
						The cycles per second /hertz/ of the power line alternating current.AHBB
					 
					
						Power Line Frequency Rating Per Function In Hertz:
					
					
						60.0 3rd radio interference					
				 
							
					
						MRC:
						The level of electrical flow,per function,for which the item is designed to operate,expressed in ampers.AHBC
					 
					
						Operating Current Rating Per Function In Amps:
					
					
						3.0 1st radio interference					
				 
							
					
						MRC:
						The level of electrical flow,per function,for which the item is designed to operate,expressed in ampers.AHBC
					 
					
						Operating Current Rating Per Function In Amps:
					
					
						3.0 3rd radio interference					
				 
							
					
						MRC:
						The level of electrical flow,per function,for which the item is designed to operate,expressed in ampers.AHBC
					 
					
						Operating Current Rating Per Function In Amps:
					
					
						3.0 2nd radio interference					
				 
							
					
						MRC:
						Indicates the type of principal circuitry per function interconnected within the item to produce the desired frequency versus attenuation characteristics.AHBL
					 
					
						Principal Circuitry Type Per Function:
					
					
						Inductance-capacitance 1st radio interference					
				 
							
					
						MRC:
						Indicates the type of principal circuitry per function interconnected within the item to produce the desired frequency versus attenuation characteristics.AHBL
					 
					
						Principal Circuitry Type Per Function:
					
					
						Inductance-capacitance 2nd radio interference					
				 
							
					
						MRC:
						Indicates the type of principal circuitry per function interconnected within the item to produce the desired frequency versus attenuation characteristics.AHBL
					 
					
						Principal Circuitry Type Per Function:
					
					
						Inductance-capacitance 3rd radio interference					
				 
							
					
						MRC:
						The identifying numeric code of the originator that controls or manufactures the input terminal.AHBN
					 
					
						Input Terminal Manufacturer Code:
					
					
						81349					
				 
							
					
						MRC:
						The specification,standard,or manufacturers identification number or symbol used to identify the input terminal.AHBP
					 
					
						Input Terminal Identification:
					
					
						Ms3102r20-15p					
				 
							
					
						MRC:
						The identifying numeric code of the originator that controls or manufactures the output terminal.AHBS
					 
					
						Output Terminal Manufacturer Code:
					
					
						81349					
				 
							
					
						MRC:
						The specification,standard,or manufacturers identification number or symbol used to identify the output terminal.AHBT
					 
					
						Output Terminal Identification:
					
					
						Ms3102r20-15s					
				 
							
					
						MRC:
						The maximum permissible temperature increase in the item as a result of its operation under normal conditions.AHCG
					 
					
						Maximum Tempurature Rise:
					
					
						25.0 degrees celsius					
				 
							
					
						MRC:
						Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
					 
					
						Inclosure Type:
					
					
						Encased					
				 
							
					
						MRC:
						Indicates the type and number of facilities by which the item is mounted.AXHR
					 
					
						Mounting Facility Type And Quantity:
					
					
						8 unthreaded hole					
				 
							
					
						MRC:
						Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
					 
					
						Features Provided:
					
					
						Moisture resistant and shock resistant					
				 
							
					
						MRC:
						Indicates the functional type and number of terminals providing electrical connection to the item.CQDW
					 
					
						Functional Terminal Type And Quantity:
					
					
						1 connector,  receptacle input-ground 1st function					
				 
							
					
						MRC:
						Indicates the functional type and number of terminals providing electrical connection to the item.CQDW
					 
					
						Functional Terminal Type And Quantity:
					
					
						1 connector,  receptacle output-ground 2nd function					
				 
							
					
						MRC:
						The level of electrical potential and type of current,per function,for which the item is designed.CQGC
					 
					
						Operating Voltage Rating And Type Per Function:
					
					
						115.0 volts ac 1st radio interference 1st function					
				 
							
					
						MRC:
						The level of electrical potential and type of current,per function,for which the item is designed.CQGC
					 
					
						Operating Voltage Rating And Type Per Function:
					
					
						115.0 volts ac 2nd radio interference 2nd function					
				 
							
					
						MRC:
						The level of electrical potential and type of current,per function,for which the item is designed.CQGC
					 
					
						Operating Voltage Rating And Type Per Function:
					
					
						115.0 volts ac 3rd radio interference 3rd function					
				 
							
					
						MRC:
						The chemical compound or mechanical mixture properties of which the body is fabricated.CQRG
					 
					
						Body Material:
					
					
						Metal					
				 
							
					
						MRC:
						The metallic,nonmetallic,and/or chemical properties with which the body is plated,dipped and/or coated. the treatment is designed to protect the body surface/s/ and cannot be wiped off.CRST
					 
					
						Body Surface Treatment:
					
					
						Tin