Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Thermal Relay
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
1.437 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
0.875 inches
MRC:
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
Environmental Protection:
Hermetic
MRC:
The designation that identifies the schematic diagram of the contact configuration.APFR
Contact Arrangement:
Single pole, single throw, normally closed
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
2 unthreaded hole
MRC:
The highest voltage at which the contacts are rated for normal operating,expressed in volts.CYCS
Contact Maximum Voltage Rating In Volts:
115.0 ac and 28.0 dc
MRC:
The highest current at which the contacts are rated for normal operation,expressed in amps.CYCT
Contact Maximum Current Rating In Amps:
6.0 ac or 3.0 dc
MRC:
The amount of voltage for which the heater is designed,expressed in volts.CYCU
Heater Voltage Rating In Volts:
28.0
MRC:
The rated power that the heater can safely consume,measured in watts.CYCV
Heater Power Rating In Watts:
4.0
MRC:
A numeric value indicating the elapsed time interval of the item,expressed in seconds.CYCW
Delay Time In Seconds:
3.0 fixed operate