Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Entmilitarisierung:
Yes - DEMIL/MLI
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Check Valve
MRC:
The part that controls the flow through the item.ADQU
Flow Control Device:
Poppet
MRC:
The maximum temperature at which the item is rated to operate for an extended period of time.AEHZ
Maximum Operating Temp:
450.0 degrees fahrenheit single response
MRC:
The means used to control the operation of the valve.AQLR
Valve Operation Method:
Automatic
MRC:
The installed position for which the item is designed.BBJX
Mounting Position:
Horizontal or vertical
MRC:
The maximum pressure at which the item is rated for operation.CQGM
Maximum Operating Pressure:
6000.0 pounds per square inch single response
MRC:
The master requirement codes of those requirements which are technically critical by reason of tolerance,fit,performance,or other characteristics which affect identification of the item.CRTL
Criticality Code Justification:
Zzzy
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Stainless steel
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Straight thru
MRC:
A feature of the item of supply which must be specifically recorded when the reference number covers a range of items.ZZZY
Reference Number Differentiating Characteristics:
Material will be in accordance with ships parts control center activity hx quality control, manufacturing and testing specifications