Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
			 
							
					
						Informationen zum Teil
						This solid-state timer relay can be set to time ranges of 0.1 to 1.0 seconds,  1.0 to 10.0 seconds,  0.1 to 1.0 minutes,  and 1.0 to 10.0 minutes by changing one of four white multiplier keys;  time limit contact is dpdt;  operating voltage is 85 to 110 percent of 120 vac;  power consumption is 2 va ;  insulation resistance is 100 megohms;  withstands dielectric strength of 2000 vac;  vibration and shock resistant;  ambient operating temperature is minus 10 to plus 50 deg. C;  ambient storage temperature is minus 25 to plus 80 deg. C;  relative humidi type 45 to 85 percent;  has power on and time-up indicators;  standard surface mount can be flush mounted using adaptor p/n y92f-40,  cage 61964
					 
				 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Electromagnetic Relay				
			 
			
										
					
						MRC:
						The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
					 
					
						Overall Length:
					
					
						50.0 millimeters 					
				 
							
					
						MRC:
						The distance measured in a straight line from the bottom to the top of an item.ABKW
					 
					
						Overall Height:
					
					
						81.6 millimeters 					
				 
							
					
						MRC:
						An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
					 
					
						Overall Width:
					
					
						40.0 millimeters 					
				 
							
					
						MRC:
						The cycles per second /hertz/ of the alternating current.AJSS
					 
					
						Frequency In Hertz:
					
					
						Between 50.0 and 60.0 					
				 
							
					
						MRC:
						Indicates the type of duty provided.APNP
					 
					
						Duty Type:
					
					
						Continuous					
				 
							
					
						MRC:
						Indicates the type and number of facilities by which the item is mounted.AXHR
					 
					
						Mounting Facility Type And Quantity:
					
					
						1 plug-in terminal single mounting facility					
				 
							
					
						MRC:
						The amount and type of voltage required at designated temperature to be applied to the input or energizing element of the item to ensure normal operation of the switching elements.CSXF
					 
					
						Operating Voltage Rating And Type At Specificationified Temp:
					
					
						120.0 volts ac 25 degrees celsius all windings					
				 
							
					
						MRC:
						The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.CTDL
					 
					
						Main Contact Load Current Rating At Maximum Rated Voltage:
					
					
						3.0 amperes ac resistive load					
				 
							
					
						MRC:
						The highest voltage at which the main contacts are rated for normal operation,expressed in volts.CWAB
					 
					
						Main Contact Maximum Voltage Rating In Volts:
					
					
						250.0 ac					
				 
							
					
						MRC:
						Indicates the type and number of terminals for providing electrical connection.TTQY
					 
					
						Terminal Type And Quantity:
					
					
						8 standard tube base all functions