Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Teilenummer:
h4s114abr
Entmilitarisierung:
Yes - DEMIL/MLI
Lagerfähigkeit:
Maßeinheit:
NIIN:
011276730
NSN
Nationale Bestandsnummer:
4320-01-127-6730 4320011276730
TXT
Beschreibung:
Centrifugal Pump
INC
INC
Artikelname-Code:
14741
INC
COM
Beachtung:
MRC:
The number of stages incorporated in the item.AAYD
Stage Quantity:
1
MRC:
The number of intake connections included on the item.AAYT
Intake Connection Quantity:
1
MRC:
Indicates the type of intake connection included on the item.AAYU
Intake Connection Type:
Threaded internal
MRC:
The number of discharge connections included on the item.AAYV
Discharge Connection Quantity:
1
MRC:
Indicates the type of discharge connection included on the item.AAYW
Discharge Connection Type:
Threaded internal
MRC:
Indicates the type of connection between the prime mover and the shaft.AAYX
Drive Connection Type:
Flexible coupled
MRC:
The type of service with which the item is designed to be used.ACKL
Media For Which Designed:
Water, fresh
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Waste heat recovery system onboard 270 ft wmec class coast guard vessels
MRC:
The maximum rated capacity delivered by the item.AHYV
Maximum Discharge Flow Rate:
15.0 gallons per minute
MRC:
The speed of the item required to produce its rated capacity.AHYZ
Operating Speed At Rated Capacity:
1750.0 revolutions per minute
MRC:
The position in which the pumping element/s/ is designed to operate.AHZA
Pumping Element Operating Position:
Horizontal
MRC:
The direction in which the pump shaft turns during operation.AHZD
Pump Rotation Direction:
Clockwise
MRC:
The design of a centrifugal pump as determined by the direction of media flow with respect to the axis of the shaft.AHZE
Centrifugal Pump Design:
Radial flow
MRC:
The number of impellers incorporated in the centrifugal pump.AHZF
Centrifugal Pump Impeller Quantity:
1
MRC:
Indicates the type of suction produced by the impeller of the centrifugal pump.AHZG
Centrifugal Pump Impeller Suction Type:
Single
MRC:
Indicates the type of drive shaft by the physical configuration,condition,and the like of the shaft end.AJAB
Drive Shaft Type:
Woodruff keyway
MRC:
The length of a straight line which passes through the center of the drive shaft end,and terminates at the circumference.AJAC
Drive Shaft End Diameter:
0.590 inches
MRC:
A measurement of the distance the drive shaft extends from the housing.AJAD
Drive Shaft Length:
1.000 inches
MRC:
Designates the thread diameter,series/type,and number of threads per measurement scale of the discharge connection.ASAZ
Discharge Connection Thread Size And Series/type Designator:
1.250-11-1/2 npt
MRC:
Designates the thread diameter,series/type,and number of threads per measurement scale of the intake connection.ASWT
Intake Connection Thread Size And Series/type Designator:
1.250-11-1/2 npt

Ähnlich Centrifugal Pumps