Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Entmilitarisierung:
Yes - DEMIL/MLI
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Linear Microcircuit
MRC:
The maximum amount of electrical energy that can be expended by an item.AEHX
Maximum Power Dissipation Rating:
1.29 watts
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
-55.0/+125.0 degrees celsius
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Low power and uncompensated
MRC:
Indicates the physical configuration of the inclosure.CQSZ
Inclosure Configuration:
Dual-in-line
MRC:
The basic purpose and number of functions of the device,modified by its intended use.CSSL
Design Function And Quantity:
4 amplifier, operational, linear
MRC:
The value of the voltage applied and type of specific electrical characteristic for which the item is designed.CZEN
Voltage Rating And Type Per Characteristic:
5.0 volts positive power supply span and 15.0 volts positive power supply span and -5.0 volts negative power supply span and -15.0 volts negative power supply span
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
14 printed circuit