Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Electric Desiccant Dehumidifier
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
34.000 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
34.750 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
31.750 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
Indicates the type of drying agent used in the item.AZSZ
Desiccant Type:
Silica gel
MRC:
The number of desiccant beds provided.AZTB
Err Default:
Err default
MRC:
The number of desiccant beds provided.AZTB
Desiccant Bed Quantity:
2
MRC:
The amount of dehumidified air delivered by the item.AZTC
Dehumidified Air Delivery:
125.000 cubic feet per minute
MRC:
The pressure of dehumidified air delivered by the item.AZTD
Err Default:
Err default
MRC:
The pressure of dehumidified air delivered by the item.AZTD
Dehumidified Air Delivery Pressure:
2.000 inches of water
MRC:
The amount of reactivated air delivered by the item.AZTE
Err Default:
Err default
MRC:
The amount of reactivated air delivered by the item.AZTE
Reactivated Air Delivery:
40.000 cubic feet per minute
MRC:
The pressure of the reactivated air delivered by the item.AZTF
Err Default:
Err default
MRC:
The pressure of the reactivated air delivered by the item.AZTF
Reactivated Air Delivery Pressure:
0.400 inches of water
MRC:
The amount of water removed by the item each hour of operation,expressed by weight.AZTG
Water Weight Removed Per Operational Hour:
5.300 pounds
MRC:
The input relative humidity of the item,expressed in percent.AZTJ
Input Relative Humidity In Percent:
85.0
MRC:
The input temperature rating of the item.CWLW
Err Default:
Err default
MRC:
The input temperature rating of the item.CWLW
Input Tempurature Rating:
75.0 degrees fahrenheit
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
120.0
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
208.0
MRC:
The number of alternating current phases.FAAZ
Phase:
Three
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
60.0