Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Entmilitarisierung:
Yes - DEMIL/MLI
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Radiacmeter
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
4.000 inches
MRC:
A measurement of the longest straight line across a circular cross-sectional plane.ADAV
Overall Diameter:
0.490 inches
MRC:
The means of attaching the item.ADJH
Mounting Method:
Any acceptable
MRC:
The element,compound,or mixture of which the case is fabricated,excluding any surface treatment.ADTV
Case Material:
Aluminum
MRC:
Consists of plating,dip,and/or coating that cannot be wiped off. plating and/or coating is any chemical and/or metallic additive,electrochemical,or mild mechanical process which protects the surface of the case.ADTY
Case Surface Treatment:
Anodized
MRC:
An indication of whether or not a container from which the item is completely removable in normal operable condition is provided.AFJU
Carrying Case:
Not provided
MRC:
The name assigned to the item by the joint electronics type designation system.AKWA
Joint Electronics Type Designation System Item Name:
Radiacmeter
MRC:
The type number assigned to the item by the joint electronics type designation system.AKWB
Joint Electronics Type Designation System Item Type Number:
Type im-9f/pd
MRC:
Indicates the type of device used to register the condition(s).AMKD
Indicator Type:
Optical quartz fiber electrometer
MRC:
Indicates the radiation type and function.AMRM
Radiation Type And Function:
Gamma rays measures
MRC:
Indicates the radiation type and function.AMRM
Radiation Type And Function:
X-rays measures
MRC:
Indicates the type of detecting element included.AMRX
Detecting Element Type:
Ionization chamber
MRC:
An indication of whether or not the item is portable.APCB
Portability:
Portable
MRC:
The minimum and maximum amount of radiation detected per hour.APPJ
Radiation Range Per Hour:
+0.0/+0.2 roentgens
MRC:
The minimum and maximum amount of radiation detected per hour.APPJ
Radiation Range Per Hour:
+0.0 to 0.2 roentgens
MRC:
The minimum and maximum number of single responses per minute.APPK
Count Range Per Minute:
Not rated
MRC:
The value of electrical potential to which an item will respond.APPP
Input Sensitivity Voltage Rating:
Any acceptable
MRC:
An indication of the energy dependence rating of the item.APPQ
Energy Dependence Rating:
+0.080/+2.000 mev
MRC:
An indication of the energy dependence rating of the item.APPQ
Energy Dependence Rating:
+0.080 to 2.000 mev