Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
					
						Teilenummer:
						iulhk111-1rec4r-66-5.00-ae-01					
 
					
					
					
					
				 
			 
							
					
						Informationen zum Teil
						Magnetic circuit protector
					 
				 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Circuit Breaker				
			 
			
										
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
					 
					
						Body Style:
					
					
						Multipole-multiple actuator type					
				 
							
					
						MRC:
						A measurement of the longest dimension of the body,in distinction from width.ADAQ
					 
					
						Body Length:
					
					
						63.25 millimeters 					
				 
							
					
						MRC:
						A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
					 
					
						Body Width:
					
					
						57.53 millimeters 					
				 
							
					
						MRC:
						The element,compound,or mixture of which the case is fabricated,excluding any surface treatment.ADTV
					 
					
						Case Material:
					
					
						Plastic					
				 
							
					
						MRC:
						The center to center distance between terminals parallel to the length of the item.AEBP
					 
					
						Center To Center Distance Between Terminals Parallel To Length:
					
					
						33.32 millimeters 					
				 
							
					
						MRC:
						The center to center distance between terminals parallel to the width of the item.AEBQ
					 
					
						Center To Center Distance Between Terminals Parallel To Width:
					
					
						19.05 millimeters 					
				 
							
					
						MRC:
						The distance between centerlines of mounting facilities parallel to the length of the item.AEBY
					 
					
						Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
					
					
						33.32 millimeters 					
				 
							
					
						MRC:
						The distance between centerlines of mounting facilities parallel to the width of the item.AEHA
					 
					
						Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
					
					
						19.05 millimeters 					
				 
							
					
					
						Boss Height:
					
					
						3.30 millimeters 					
				 
							
					
					
						Mounting Surface To Terminal End Distance:
					
					
						51.82 millimeters 					
				 
							
					
						MRC:
						The number of poles included in the item.AKPX
					 
					
						Pole Quantity:
					
					
						3					
				 
							
					
						MRC:
						Indicates the type and number of facilities by which the item is mounted.AXHR
					 
					
						Mounting Facility Type And Quantity:
					
					
						6 threaded stud					
				 
							
					
						MRC:
						The maximum current load that each pole is rated to carry continuously.CPLM
					 
					
						Maximum Continuous Load Current Rating Per Pole:
					
					
						5.0 amperes ac all locations					
				 
							
					
						MRC:
						Indicates the type and value of operating voltage for which each pole is designed to operate,expressed in volts.CPRF
					 
					
						Operating Voltage Type And Rating Per Pole In Volts:
					
					
						277.0 ac  and 480.0 ac all locations					
				 
							
					
						MRC:
						Indicates the type of electrical condition that will cause the device to trip.CPRH
					 
					
						Circuit Protection Type:
					
					
						Undercurrent all locations					
				 
							
					
						MRC:
						The means by which the trip mechanism is released.CPRJ
					 
					
						Trip Release Method:
					
					
						Magnetic all locations					
				 
							
					
						MRC:
						Denotes the type of trip release action.CPRL
					 
					
						Trip Release Characteristic:
					
					
						Instantaneous all locations					
				 
							
					
						MRC:
						The means provided to reposition the mechanism so that the device is ready to function.CPRQ
					 
					
						Reset Method:
					
					
						Manual					
				 
							
					
						MRC:
						Indicates the type of mechanism provided for tripping main contacts.CPRR
					 
					
						Main Contact Tripping Mechanism Type:
					
					
						Trip free					
				 
							
					
						MRC:
						Indicates the type and number of actuators provided for manual control.CPRT
					 
					
						Manual Actuator Type And Quantity:
					
					
						3 toggle					
				 
							
					
						MRC:
						The basic internal electrical configuration of the trip mechanism.CPSM
					 
					
						Internal Trip Release Configuration:
					
					
						Series trip all locations					
				 
							
					
						MRC:
						The amount of current,expressed in amperes,and the type for which the switch is rated.CSSX
					 
					
						Switch Current Rating And Type In Amps:
					
					
						20.0 ac					
				 
							
					
						MRC:
						Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
					 
					
						Special Features:
					
					
						3 poles,  5 amp rated current					
				 
							
					
						MRC:
						The cycles per second /hertz/ of the alternating current.FREQ
					 
					
						Frequency In Hertz:
					
					
						60.0 all locations					
				 
							
					
						MRC:
						Indicates the type and number of terminals for providing electrical connection.TTQY
					 
					
						Terminal Type And Quantity:
					
					
						6 threaded stud