Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Teilenummer:
jd1n108p253ua
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Nonwire Wound Variable Resistor
MRC:
The number of individual elements.AAPN
Section Quantity:
2
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Cylindrical bushing mounted
MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Not established
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
2.391 inches
MRC:
The length of a straight line which passes through the center of the body,and terminates at the circumference.ABPM
Body Diameter:
1.156 inches
MRC:
The length of a straight line which passes through the center of a shaft,and terminates at the circumference.ABWV
Shaft Diameter:
0.250 inches
MRC:
A measurement of the longest dimension of the shaft,in distinction from width.ABXF
Shaft Length:
1.125 inches
Mounting Bushing Length:
0.375 inches
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
1.266 inches
MRC:
A measurement of the longest straight line across a circular cross-sectional plane.ADAV
Overall Diameter:
1.484 inches
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the shaft.AEDX
Shaft Style:
Round
MRC:
Indicates the type of shaft bearing/s/ furnished.AEDZ
Shaft Bearing Type:
Bearing
MRC:
Indicates the type of facility or arrangement provided for moving the variable contact(s).AEFD
Actuator Type:
Single shaft
MRC:
Indicates the location of a mechanical device which prevents the turning of the item on its mounted surface,expressed by the twelve hour clock designation.AEFN
Nonturn Device Location:
At 3 oclock and at 9 oclock
MRC:
The linear measurement of the distance from the actuator centerline to the centerline of the nonturn device.AEFP
Nonturn Device Radius:
0.531 inches
MRC:
The length of a straight line which passes through the center of a coaxial cylinder which would bound the crest of an external thread or the root of an internal thread.AJYN
Screw Thread Diameter:
0.375 inches
MRC:
A designation distinguishing one group of screw thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.AJYP
Screw Thread Series Designator:
Unef
MRC:
The number of screw threads on the item per linear inch measured on a line parallel to the thread axis,including incomplete threads.AJYQ
Screw Thready Qty Per Inch (tpi):
32.0
MRC:
The position of the terminal/s/ for making connection to an item.APXH
Terminal Location:
Radially positioned over less than half the circumference
MRC:
The means of attaching the item.AXGY
Mounting Method:
Standard bushing
MRC:
A measure of the opposition to the flow of direct or alternating current per section.CQCC
Electrical Resistance Per Section:
25.000 kilohms 1st section and 25.000 kilohms 2nd section
MRC:
The permissible range per section by which the actual value of resistance or voltage at any specified point may deviate from the theoretical value for the linear or nonlinear function,expressed as a minus and plus percent.CQFL
Function Conformity Tolerance Per Section:
-0.50/+0.50 all sections
MRC:
The maximum amount of electrical energy that can be expended per section,expressed in watts.CRGD
Power Dissipation Rating Per Section In Watts:
2.0 free air single section
MRC:
The fidelity of the relationship between the actual function characteristics and the theoretical function per section.CRGM
Function Conformity Per Section:
Single section independent linearity
MRC:
The limits of permissible variation in the electrical resistance value per section of an item from its rated value,expressed in percent.CRSS
Resistance Tolerance Per Section In Percent:
-10.0/+10.0 1st section and -10.0/+10.0 2nd section
MRC:
The specified mathematical relation per section between the terminal resistance,or output ratio,and the rotation of the actuator.CSBX
Function Characteristic Per Section:
All sections linear
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
6 tab, solder lug