Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Teilenummer:
l9467-101-001
Informationen zum Teil
72 in. H, 60 in. W, 96 in. D, ; used on b1-b acft
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Hydraulic Pumping Uni Test Stand
MRC:
The amount of hydraulic fluid required to operate the item.AAYJ
Hydraulic Fluid Flow Rate:
135.0 gallons per minute
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Dc
MRC:
Indicates the type of drive for turning,rotating,or positioning the mechanism.AKCV
Drive Type:
Hydraulic motor
MRC:
Indicates the designed use of the item.ALBY
Usage Design:
Aircraft hydraulic system
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Portable
MRC:
An indication of the rated horsepower of the item.ANCY
Horsepower Rating:
Not rated
MRC:
The source of power which drives the item.ATJK
Power Source:
Electric motor
MRC:
The maximum speed at which the item is designed to operate,expressed in revolutions per minute.ATPR
Maximum Speed Rating In Rpm:
Not rated
MRC:
An indication of whether or not an accumulator is included.AYJM
Accumulator:
Included
MRC:
The pressure at which an item is designed to operate.BGST
Pressure Rating:
4000.0 pounds per square inch
MRC:
The maximum pressure at which the item is designed to operate.BJDW
Maximum Operating Pressure:
4250.0 pounds per square inch
MRC:
An indication of whether or not a design feature for testing engine driven hydraulic pumps is included.CGYK
Engine Driven Hydraulic Pump Testing Design Feature:
Included
MRC:
The rated flow capacity of the item.CGYL
Flow Capacity Rating:
64.5 gallons per minute
MRC:
An indication of whether or not a pressure manifold subcircuit(s) is included.CGYM
Pressure Manifold Subcircuit:
Not included
MRC:
An indication of whether or not a filtering system is included.CHGQ
Filtering System:
Included
MRC:
An indication of whether or not a pressure and suction hose are included.CHGR
Pressure/suction Hose:
Included
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
Not rated
MRC:
Describes the capabilities,intended use,and/or purpose for which the item is provided.FTLD
Functional Description:
Provides hydraulic fluid hook-up, pressure and flow capacity, torque sensing, elec stimuli, controls, and computerized monitoring capability to fault isolate, adjust and verify the operational integrity of the engine driven hydraulic pump lru; also tests the electrically operated solenoid for dielectric withstanding voltage
MRC:
Literature and references available for information pertaining to the item.RDAL
Reference Data And Literature:
Serd no. 450376