Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
			 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Centrifugal Pump Unit				
			 
			
										
					
						MRC:
						The number of prime movers incorporated in the unit.AAXH
					 
					
						Prime Mover Quantity:
					
					
						1					
				 
							
					
						MRC:
						The number of stages incorporated in the item.AAYD
					 
					
						Stage Quantity:
					
					
						1					
				 
							
					
						MRC:
						The number of discharge connections included on the item.AAYV
					 
					
						Discharge Connection Quantity:
					
					
						1					
				 
							
					
						MRC:
						Indicates the type of discharge connection included on the item.AAYW
					 
					
						Discharge Connection Type:
					
					
						Threaded external					
				 
							
					
						MRC:
						Indicates the type of current whether alternating,direct,or both.ACDC
					 
					
						Current Type:
					
					
						Ac					
				 
							
					
						MRC:
						The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
					 
					
						Environmental Protection:
					
					
						Waterproof					
				 
							
					
						MRC:
						The number of pumps incorporated in the item.AENC
					 
					
						Pump Quantity:
					
					
						1					
				 
							
					
						MRC:
						The maximum rated capacity delivered by the item.AHYV
					 
					
						Maximum Discharge Flow Rate:
					
					
						4.0 gallons per minute					
				 
							
					
						MRC:
						The sum of the total discharge head and the total suction lift.AHYX
					 
					
						Total Head:
					
					
						12.000 feet					
				 
							
					
						MRC:
						The position in which the pumping element/s/ is designed to operate.AHZA
					 
					
						Pumping Element Operating Position:
					
					
						Horizontal					
				 
							
					
						MRC:
						The design of a centrifugal pump as determined by the direction of media flow with respect to the axis of the shaft.AHZE
					 
					
						Centrifugal Pump Design:
					
					
						Radial flow					
				 
							
					
						MRC:
						Indicates the type of prime mover included with the unit.AKDJ
					 
					
						Prime Mover Type:
					
					
						Electric motor					
				 
							
					
						MRC:
						Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
					 
					
						Inclosure Type:
					
					
						Fully enclosed					
				 
							
					
						MRC:
						Designates the thread diameter,series/type,and number of threads per measurement scale of the discharge connection.ASAZ
					 
					
						Discharge Connection Thread Size And Series/type Designator:
					
					
						0.500-14 npt					
				 
							
					
						MRC:
						The rated power of the prime mover.CSYL
					 
					
						Prime Mover Power Rating:
					
					
						0.028 horsepower					
				 
							
					
						MRC:
						The total electrical voltage.ELEC
					 
					
						Voltage In Volts:
					
					
						115.0					
				 
							
					
						MRC:
						The cycles per second /hertz/ of the alternating current.FREQ
					 
					
						Frequency In Hertz:
					
					
						60.0