Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
					
						Teilenummer:
						lelk11-1rec4-32066-1-v					
 
					
					
					
					
				 
			 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Circuit Breaker				
			 
			
										
					
						MRC:
						The element,compound,or mixture of which the case is fabricated,excluding any surface treatment.ADTV
					 
					
						Case Material:
					
					
						Plastic					
				 
							
					
						MRC:
						The number of poles included in the item.AKPX
					 
					
						Pole Quantity:
					
					
						2					
				 
							
					
						MRC:
						The means of quenching an arc.APNQ
					 
					
						Arc Quenching Method:
					
					
						Magnetic blowout					
				 
							
					
						MRC:
						Indicates the type and number of facilities by which the item is mounted.AXHR
					 
					
						Mounting Facility Type And Quantity:
					
					
						4 threaded hole					
				 
							
					
						MRC:
						The maximum current load that each pole is rated to carry continuously.CPLM
					 
					
						Maximum Continuous Load Current Rating Per Pole:
					
					
						100.0 amperes dc second location					
				 
							
					
						MRC:
						Indicates the type and value of operating voltage for which each pole is designed to operate,expressed in volts.CPRF
					 
					
						Operating Voltage Type And Rating Per Pole In Volts:
					
					
						15.0 dc first location					
				 
							
					
						MRC:
						Indicates the type and value of operating voltage for which each pole is designed to operate,expressed in volts.CPRF
					 
					
						Operating Voltage Type And Rating Per Pole In Volts:
					
					
						80.0 dc second location					
				 
							
					
						MRC:
						Indicates the type of electrical condition that will cause the device to trip.CPRH
					 
					
						Circuit Protection Type:
					
					
						Overcurrent second location					
				 
							
					
						MRC:
						The means by which the trip mechanism is released.CPRJ
					 
					
						Trip Release Method:
					
					
						Magnetic-hydraulic all locations					
				 
							
					
						MRC:
						Denotes the type of trip release action.CPRL
					 
					
						Trip Release Characteristic:
					
					
						Time delay second location					
				 
							
					
						MRC:
						The means provided to reposition the mechanism so that the device is ready to function.CPRQ
					 
					
						Reset Method:
					
					
						Manual					
				 
							
					
						MRC:
						Indicates the type of mechanism provided for tripping main contacts.CPRR
					 
					
						Main Contact Tripping Mechanism Type:
					
					
						Trip free					
				 
							
					
						MRC:
						Indicates the type and number of actuators provided for manual control.CPRT
					 
					
						Manual Actuator Type And Quantity:
					
					
						1 toggle					
				 
							
					
						MRC:
						Denotes the action imparted by actuator operation.CPRW
					 
					
						Actuator Function:
					
					
						Trip-reset					
				 
							
					
						MRC:
						Indicates the type of protection for which the inclosure is designed.CQXF
					 
					
						Inclosure Protection Type For Which Designed:
					
					
						Fungus resistant