Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Teilenummer:
ljs-10a-24-0v-6453
Entmilitarisierung:
Yes - DEMIL/MLI
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Power Supply
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
7.203 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
4.531 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
2.047 inches
MRC:
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
Environmental Protection:
Fungus proof
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
145.0 dc pounds per hour wet 2nd operating power rqmt
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
105.0 ac pounds per hour dry 1st operating power rqmt and 132.0 ac pounds per hour with retaining chain 1st operating power rqmt
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
24.0 dc volts single power output
MRC:
The number of complete cyclic changes,per unit of time,for which the input is rated.APTQ
Input Frequency Rating:
47.0 hertz 1st operating power rqmt and 440.0 hertz 1st operating power rqmt
MRC:
The ambient temperature range at which the item is designed to operate.AYNH
Operating Ambient Tempurature Range:
+0.1/+71.0 degrees celsius
MRC:
The number of output control(s) provided.BGHX
Output Control Quantity:
1 single power output
MRC:
Indicates the type of output control provided.BGHY
Output Control Type:
Voltage adjustment single power output
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Over voltage protector and over current protector and fuse
MRC:
The maximum alternating current voltage variation which may be present on the direct current output voltage level.CWGZ
Ripple Voltage At Full Load:
15.0 millivolts rms single power output
MRC:
Indicates the location of the output control(s).CWHC
Output Control Location:
Front panel single power output
MRC:
Indicates the type of electrical output connection.CWHJ
Output Connection Type:
Quick disconnect single power output
MRC:
Indicates the type of electrical input connection.CWHQ
Input Connection Type:
Quick disconnect 1st operating power rqmt
MRC:
Indicates the type of electrical input connection.CWHQ
Input Connection Type:
Quick disconnect 2nd operating power rqmt