Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Informationen zum Teil
Remote sensing; power supply
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Power Supply
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
15.000 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
3.812 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
4.281 inches
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Pacer dawn
MRC:
The relationship of the electrical power source to the item.AKWC
Electrical Power Source Relationship:
Operating
MRC:
The number of input alternating current phase(s).ANPM
Input Phase:
Single 1st alternate operating power rqmt
MRC:
The number of input alternating current phase(s).ANPM
Input Phase:
Single 2nd alternate operating power rqmt
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
170.0 ac pounds per hour dry 2nd alternate operating power rqmt and 265.0 ac pounds per hour with retaining chain 2nd alternate operating power rqmt
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
85.0 ac pounds per hour dry 1st alternate operating power rqmt and 132.0 ac pounds per hour with retaining chain 1st alternate operating power rqmt
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
0.0 dc volts 1st power output and 40.0 dc volts 1st power output
MRC:
The number of complete cyclic changes,per unit of time,for which the input is rated.APTQ
Input Frequency Rating:
47.0 hertz 1st alternate operating power rqmt and 63.0 hertz 1st alternate operating power rqmt
MRC:
The number of complete cyclic changes,per unit of time,for which the input is rated.APTQ
Input Frequency Rating:
47.0 hertz 2nd alternate operating power rqmt and 63.0 hertz 2nd alternate operating power rqmt
MRC:
The ambient temperature range at which the item is designed to operate.AYNH
Operating Ambient Tempurature Range:
+0.1/+71.0 degrees celsius
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Over current protector and over voltage protector and voltage adjustment and on-off switch-indicator
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
5.0 dc amperes 1st power output and 7.0 dc amperes 1st power output
MRC:
Indicates the type of design provided for ventilation of the item.CWKG
Ventilation Design Type:
Single fan