Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Entmilitarisierung:
Yes - DEMIL/MLI
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Power Supply
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
9.000 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
6.250 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
8.750 inches
MRC:
The number of input alternating current phase(s).ANPM
Input Phase:
Single single operating power rqmt
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
115.0 ac pounds per hour wet single operating power rqmt
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
115.0 ac volts single operating power rqmt
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
200.0 dc volts 1st power output and 325.0 dc volts 1st power output
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
6.3 ac volts 2nd power output
MRC:
The number of complete cyclic changes,per unit of time,for which the input is rated.APTQ
Input Frequency Rating:
50.0 hertz single operating power rqmt and 60.0 hertz single operating power rqmt
MRC:
The means used to change alternating current voltage to direct current voltage.BHQN
Rectification Method:
Single phase full wave center tap
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Filter
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
0.0 dc milliamperes 1st power output and 100.0 dc milliamperes 1st power output
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
3.0 dc milliamperes 2nd power output