Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Teilenummer:
m27500-12te5t14
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Electrical Power Cable
MRC:
The style designation indicating the configuration that most nearly corresponds to the cross-sectional shape of the item.AAGR
Cross Sectional Shape:
Round
MRC:
A value which expresses the degree of heat or cold as applied to the operation,or limitation of operation,of an item.ABJH
Tempurature Rating:
150.0 degrees celsius
MRC:
The number of electrical conductors included on the item.AMQN
Conductor Quantity:
5
MRC:
The number of strands per conductor.BLNZ
Strand Quantity Per Conductor:
37 all conductors
MRC:
The fabricated form of the conductor.CXCW
Conductor Form:
Stranded all conductors
MRC:
The designation used to describe the round stranded or round solid conductor size.CXDC
Round Conductor Size:
12 awg all conductors
MRC:
The american wire gage size of the individual strands of wire used in each stranded conductor.CXDG
Strand Awg Size Per Conductor:
28 all conductors
MRC:
The maximum sustained voltage that can be safely applied to the item without risking failure or damage.CXFK
Voltage Rating:
600.0 root mean square (rms) operating voltage all conductors
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Copper 1st position shield braid, metallic cable
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Copper core conductor all conductors
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Plastic ethylene-tetrafluoroethylene 1st position primary insulation all conductors
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Plastic polyvinylidene fluoride 2nd position jacket cable
MRC:
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the surface(s) and cannot be wiped off.SFTT
Surface Treatment:
Tin alloy 1st position coating cable
MRC:
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the surface(s) and cannot be wiped off.SFTT
Surface Treatment:
Tin core conductor all conductors
MRC:
The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.TEST
Test Data Document:
81349-mil-c-27500 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.).