Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Teilenummer:
m287763-025p
Informationen zum Teil
Dc; failure rate of p equals 0.1 per 10, 000 cycles
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Hybrid Relay
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
9.520 millimeters
MRC:
A measurement of the longest straight line across a circular cross-sectional plane.ADAV
Overall Diameter:
Between 6.980 millimeters and 8.510 millimeters
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
-65.0/+125.0 degrees celsius
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Pacer dawn
MRC:
The value(s) of potential for which the item is rated.AMSE
Voltage Rating:
0.2 volts dropout
MRC:
The value(s) of potential for which the item is rated.AMSE
Voltage Rating:
1.4 volts hold
MRC:
The value(s) of potential for which the item is rated.AMSE
Voltage Rating:
2.8 volts pickup
MRC:
The value(s) of potential for which the item is rated.AMSE
Voltage Rating:
5.0 volts supply and 7.0 volts supply
MRC:
The designation that identifies the schematic diagram of the contact configuration.APFR
Contact Arrangement:
Double pole, double throw
MRC:
The amount of current for which the item is designed.AXNP
Current Rating:
1.00 amperes resistive
MRC:
The amount of current for which the item is designed.AXNP
Current Rating:
43.50 milliamperes coil and 59.30 milliamperes coil
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Diode coil suppression and hermetically sealed and transistor driven
MRC:
The interval for which the item,by design,is purposely delayed between introduction of power into the energizing element and completion of travel of the contact carrier,and/or between interruption of the energizing power and return of the contact carrier to its normal de-energizing position.CRXH
Time Delay:
4.00 milliseconds turn-on
MRC:
The interval for which the item,by design,is purposely delayed between introduction of power into the energizing element and completion of travel of the contact carrier,and/or between interruption of the energizing power and return of the contact carrier to its normal de-energizing position.CRXH
Time Delay:
7.50 milliseconds turn-off
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
9 uninsulated wire lead