Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Entmilitarisierung:
Yes - DEMIL/MLI
Informationen zum Teil
Key code lee
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Standardized Electronic Module
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
2.620 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
0.290 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
1.950 inches
MRC:
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
Environmental Protection:
Salt spray resistant and vibration
MRC:
The number of individual sections included in the item.AFBH
Individual Section Quantity:
2
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
+0.0/+60.0 degrees celsius
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
+0.0 to 60.0 degrees celsius
MRC:
The numeric value of the life expectancy of the item.AFHH
Average Life Rating:
500.0
MRC:
The minimum and maximum temperatures at which an item can be stored without detrimental effect.AFJQ
Storage Tempurature Range:
-62.0/+125.0 degrees celsius
MRC:
The minimum and maximum temperatures at which an item can be stored without detrimental effect.AFJQ
Storage Tempurature Range:
-62.0 to 125.0 degrees celsius
MRC:
A term used to denote the specific measurement of duration used to indicate the average life of the item.AFSU
Average Life Measurement:
Hours
MRC:
The numeric value indicating the average life expectancy for which the item is rated,expressed in hours.AFSV
Average Life Rating In Hours:
500.0
MRC:
The style designation indicating the configuration that most nearly corresponds to the basic appearance of the item.AGTA
Basic Shape Style:
Rectangular or square
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Encased
MRC:
The means by which the item is operated or controlled.ALBM
Operating Control Method:
Automatic
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Module
MRC:
Indicates the type of control.AQZF
Control Type:
Remote
MRC:
Indicates the type of circuit construction provided in the item.BHSX
Circuit Construction Type:
Solid state
MRC:
The portion of the frequency spectrum at which an item is designed to receive or transmit signal power.BHTB
Frequency Per Channel:
100.0 kilohertz 2nd output channel err-100 and 1.0 megahertz 2nd output channel err-100
MRC:
The portion of the frequency spectrum at which an item is designed to receive or transmit signal power.BHTB
Frequency Per Channel:
3.0 kilohertz 1st output channel err-100 and 100.0 kilohertz 1st output channel err-100
MRC:
The portion of the frequency spectrum at which an item is designed to receive or transmit signal power.BHTB
Frequency Per Channel:
MRC:
The rated signal voltage for each channel.BHTK
Signal Voltage Rating Per Channel:
0.000 volts input preset and 1.250 volts interstage preset
MRC:
The rated signal voltage for each channel.BHTK
Signal Voltage Rating Per Channel:
1.000 volts any acceptable preset
MRC:
The rated signal voltage for each channel.BHTK
Signal Voltage Rating Per Channel:
MRC:
The rated signal voltage for each channel.BHTK
Signal Voltage Rating Per Channel:
1.000 volts output
MRC:
The total opposition (resistive and reactive) to the flow of alternating current per channel.BHTN
Impedance Rating Per Channel:
2.370 kilohms 2nd operating channel err-100
MRC:
The total opposition (resistive and reactive) to the flow of alternating current per channel.BHTN
Impedance Rating Per Channel:
3.200 kilohms 1st operating channel err-100
MRC:
The total opposition (resistive and reactive) to the flow of alternating current per channel.BHTN
Impedance Rating Per Channel:
2.370 kilohms 2nd operating channel
MRC:
The total opposition (resistive and reactive) to the flow of alternating current per channel.BHTN
Impedance Rating Per Channel:
3.200 kilohms 1st operating channel
MRC:
Indicates the type of signal data per channel.BHTZ
Signal Data Type Per Channel:
1st output channel analog voltage err-100
MRC:
Indicates the type of signal data per channel.BHTZ
Signal Data Type Per Channel:
2nd output channel analog voltage err-100
MRC:
Indicates the type of signal data per channel.BHTZ
Signal Data Type Per Channel:
1st output channel analog voltage
MRC:
Indicates the type of signal data per channel.BHTZ
Signal Data Type Per Channel:
2nd output channel analog voltage
MRC:
Indicates the type of connection and its location on the item.BJBP
Connection Type And Location:
Connector, plug bottom
MRC:
Indicates the type and number of contact(s) included in the connection.BJBW
Connection Contact Type And Quantity:
1 connector, plug external
MRC:
The value(s) of the potential supplied from an exterior direct current source to operate the item,expressed in volts.BKFB
External Dc Operating Voltage In Volts:
15.0 2nd voltage err-100
MRC:
The value(s) of the potential supplied from an exterior direct current source to operate the item,expressed in volts.BKFB
External Dc Operating Voltage In Volts:
-15.0 1st voltage err-100
MRC:
The value(s) of the potential supplied from an exterior direct current source to operate the item,expressed in volts.BKFB
External Dc Operating Voltage In Volts:
-15.0 1st voltage
MRC:
The value(s) of the potential supplied from an exterior direct current source to operate the item,expressed in volts.BKFB
External Dc Operating Voltage In Volts:
15.0 2nd voltage
MRC:
Markings included on an item for the purpose of offering instructions or warnings or to indicate the purpose,function,or application of the item.excludes manufacturers part numbers,symbols,or the like.MARK
Special Markings:
Amplifier, phase shift, analog
MRC:
The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.TEST
Test Data Document:
81349-mil-m-28787 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.).
MRC:
The document designator of the specification or standard which established the item of supply.ZZZK
Specification Data:
81349-mil-m-28787/221 government specification