Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Teilenummer:
m3900609-8789
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Electrolytic Fixed Capacitor
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
W/o mtg facilities, axial terminals
MRC:
Indicates the type designator,per mil-std-1276,of the detail requirements of leads used on electronic components.AARF
Mil-std-1276 Wire Lead Type Designator:
N-3 and c
MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Established
MRC:
The rate of failure determined under specified conditions to establish the reliability of an item,expressed in percent.AARH
Reliability Failure Rate Level In Percent:
0.0100
MRC:
A measurement of the longest dimension of a terminal,in distinction from width.ABJT
Terminal Length:
1.500 inches
MRC:
The length of a straight line which passes through the center of the body,and terminates at the circumference.ABPM
Body Diameter:
0.219 inches
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
0.515 inches
MRC:
The length of a straight line which passes through the center of a terminal,and terminates at the circumference.AEBT
Terminal Diameter:
0.025 inches
MRC:
A designator indicating a graphic representation,in standard and accepted symbols,of essential electrical-electronic elements and related connections on the item.AEBZ
Schematic Diagram Designator:
Electrod (s) grounded to case, w/gnd terminal
MRC:
The general construction and/or form of the anode material.AECE
Anode Type:
Solid
MRC:
The total opposition offered to the flow of an alternating or pulsating current,expressed at minimum operating temperature in ohms.AECN
Impedance At Minimum Operating Tempurature In Ohms:
500.0
MRC:
An indication of whether or not the item normally will accept flow of current in one direction only.AECQ
Electrical Polarization:
Polarized
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Hermetically sealed case
MRC:
The relative level of the quantity of electric charge at a given potential which the capacitor is capable of receiving and storing per section.CQBQ
Capacitance Value Per Section:
4.700 microfarads single section
MRC:
The temperature/s/ at which an item can function without voltage derating.CQJJ
Nonderated Operating Temp:
Between -55.0 degrees celsius and 85.0 degrees celsius
MRC:
Stray direct current of relatively small value which flows through the item when voltage is impressed across it,measured at maximum operating temperature.CQLH
Dc Leakage At Maximum Operating Temp:
2.0 microamperes
MRC:
The highest value and type of potential that may be continuously applied to the item per section at the highest operating temperature permissible without voltage derating.CQWM
Nonderated Continuous Voltage Rating And Type Per Section:
100.0 dc single section
MRC:
The limits of permissible deviation per section of a measured value from a specified value.CRTP
Tolerance Range Per Section:
-5.00/+5.00 percent single section
MRC:
The chemical compound or mechanical mixture properties of which the case is fabricated.CWJK
Case Material:
Metal
MRC:
The chemical compound or mechanical mixture properties of which the capacitive electrode is fabricated.CWNJ
Capacitive Electrode Material:
Tantalum
MRC:
The ratio of resistance to capacitive reactance measured at reference temperature.CWPM
Dissipation Factor At Reference Tempurature In Percent:
3.6000
MRC:
Stray direct current of relatively small value flows through the capacitor when voltage is impressed across it,measured at reference temperature.CWQH
Dc Leakage At Reference Temp:
1.000 microamperes
MRC:
The chemical compound or mechanical mixture properties of which the case insulation is fabricated.CWSZ
Case Insulation Material:
Plastic
MRC:
The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.TEST
Test Data Document:
81349-mil-c-39006 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.).
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
2 uninsulated wire lead
MRC:
The document designator of the specification or standard which established the item of supply.ZZZK
Specification Data:
81349-mil-c-39006/9 government specification