Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Teilenummer:
m3901408-0204
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Ceramic Dielectr Fixed Capacitor
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
W/thd bushing mtg, terminals on opposite endw/thd bushing mtg, terminals on opposite end
MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Establishedestablished
MRC:
The rate of failure determined under specified conditions to establish the reliability of an item,expressed in percent.AARH
Reliability Failure Rate Level In Percent:
1.00001.0000
MRC:
The shortest straight line between flats,perpendicular to the height of the wrenching surface.AAZK
Width Across Flats:
0.375 inches 0.375 inches
MRC:
A measurement of the longest dimension of a terminal,in distinction from width.ABJT
Terminal Length:
0.688 inches 0.688 inches
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
0.875 inches
MRC:
The length of a straight line which passes through the center of a terminal,and terminates at the circumference.AEBT
Terminal Diameter:
0.051 inches
MRC:
A designator indicating a graphic representation,in standard and accepted symbols,of essential electrical-electronic elements and related connections on the item.AEBZ
Schematic Diagram Designator:
Feedthrough
MRC:
A designation distinguishing one group of screw thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter on the mounting facility.AKEJ
Mounting Facility Screw Thread Series Designator:
Unf
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
1 threaded bushing
MRC:
Direct current resistance between two conductors that are separated by an insulating material,measured at the maximum operating temperature of the item.CQBF
Insulation Resistance At Maximum Operating Temp:
250000.0 megohms
MRC:
The relative level of the quantity of electric charge at a given potential which the capacitor is capable of receiving and storing per section.CQBQ
Capacitance Value Per Section:
1000.000 picofarads single section
MRC:
The maximum permissible capacitance change per section with temperature over the operating temperature range,measured either with or without rated voltage applied.CQFB
Voltage Tempurature Limits Per Section In Percent Capacitance Change:
-25.0/+15.0 with rated voltage applied single section
MRC:
The temperature/s/ at which an item can function without voltage derating.CQJJ
Nonderated Operating Temp:
Between -55.0 degrees celsius and 85.0 degrees celsius
MRC:
A designation that is used for the purpose of general identification of the thread.CQJX
Thread Size:
0.312 inches
MRC:
The highest value and type of potential that may be continuously applied to the item per section at the highest operating temperature permissible without voltage derating.CQWM
Nonderated Continuous Voltage Rating And Type Per Section:
1500.0 dc single section
MRC:
The limits of permissible deviation per section of a measured value from a specified value.CRTP
Tolerance Range Per Section:
-20.00/+20.00 percent single section
MRC:
The chemical compound or mechanical mixture properties of which the case is fabricated.CWJK
Case Material:
Metal
MRC:
Direct current resistance between two conductors that are separated by an insulating material,measured at reference temperature.CWPK
Insulation Resistance At Reference Temp:
500000.0 megohms
MRC:
The ratio of resistance to capacitive reactance measured at reference temperature.CWPM
Dissipation Factor At Reference Tempurature In Percent:
1.2000
MRC:
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated. the treatment is designed to protect the terminal surface(s) and cannot be wiped off.CWSG
Terminal Surface Treatment:
Solder
MRC:
The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.TEST
Test Data Document:
81349-mil-c-39014 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.).
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
2 uninsulated wire lead
MRC:
The document designator of the specification or standard which established the item of supply.ZZZK
Specification Data:
81349-mil-c-39014/8 government specification