Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
					
						Teilenummer:
						m835365-024m					
 
					
					
					
					
				 
			 
							
					
						Informationen zum Teil
						Failure rate level 1.0 percent per 10000 operations
					 
				 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Electromagnetic Relay				
			 
			
										
					
						MRC:
						The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
					 
					
						Overall Length:
					
					
						Between 1.260 inches and 1.280 inches 					
				 
							
					
						MRC:
						The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the length.ABKQ
					 
					
						Center To Center Distance Between Mounting Facilities Parallel To Length:
					
					
						1.062 inches  single mounting facility and 1.078 inches  single mounting facility					
				 
							
					
						MRC:
						The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the width.ABKR
					 
					
						Center To Center Distance Between Mounting Facilities Parallel To Width:
					
					
						0.405 inches  single mounting facility					
				 
							
					
						MRC:
						The distance measured in a straight line from the bottom to the top of an item.ABKW
					 
					
						Overall Height:
					
					
						Between 0.390 inches and 0.410 inches 					
				 
							
					
						MRC:
						An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
					 
					
						Overall Width:
					
					
						Between 0.620 inches and 0.640 inches 					
				 
							
					
						MRC:
						A measurement taken at right angles to the length of the mounting slot,in distinction from thickness.ABTD
					 
					
						Mounting Slot Width:
					
					
						0.133 inches  single mounting facility					
				 
							
					
						MRC:
						The element,compound,or mixture of which the case is fabricated,excluding any surface treatment.ADTV
					 
					
						Case Material:
					
					
						Metal					
				 
							
					
						MRC:
						The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
					 
					
						Environmental Protection:
					
					
						Hermetic					
				 
							
					
						MRC:
						The measure of sensitivity of the item to be packaged. a factor used by packaging engineers in devising proper cushioning in a package.AFJN
					 
					
						Fragility Factor:
					
					
						Moderately rugged					
				 
							
					
						MRC:
						The national stock number or the identification information of the end equipment for which the item is a part.AGAV
					 
					
						End Application:
					
					
						F/fb11 (amp) t					
				 
							
					
						MRC:
						The number of individual /not electrically connected/ windings.AKDX
					 
					
						Winding Quantity:
					
					
						1					
				 
							
					
						MRC:
						The purpose for which the item is designed.AKSL
					 
					
						Purpose For Which Designed:
					
					
						General					
				 
							
					
						MRC:
						The number of coils included on the item.APCN
					 
					
						Coil Quantity:
					
					
						1					
				 
							
					
						MRC:
						The measured opposition to the flow of direct current offered by the item winding.APNA
					 
					
						Winding Dc Resistance Rating:
					
					
						500.0 ohms  single winding					
				 
							
					
						MRC:
						Indicates the type of duty provided.APNP
					 
					
						Duty Type:
					
					
						Continuous					
				 
							
					
						MRC:
						The means of quenching an arc.APNQ
					 
					
						Arc Quenching Method:
					
					
						Air					
				 
							
					
						MRC:
						Indicates the type and number of facilities by which the item is mounted.AXHR
					 
					
						Mounting Facility Type And Quantity:
					
					
						4 slotted hole single mounting facility					
				 
							
					
						MRC:
						Indicates the type of storage space required for an item in order to provide the degree of protection necessary to maintain serviceability standards.BBRG
					 
					
						Storage Type:
					
					
						General purpose warehouse					
				 
							
					
						MRC:
						A measurement of volume taken by multiplying the length by the width by the height of an item and rendered in cubic units.CBME
					 
					
						Cubic Measure:
					
					
						0.336 cubic inches					
				 
							
					
						MRC:
						The general configuration and relative position of the facilities provided for mounting the item.CQYJ
					 
					
						Mounting Facility Pattern:
					
					
						In-line single mounting facility					
				 
							
					
						MRC:
						The designation that identifies the schematic diagram of the electrical configuration of the main nonpile-up contacts including the number of poles or forms.CRNG
					 
					
						Nonpile-up Main Contact Arrangement:
					
					
						4 pole,  double throw,  one position momentary					
				 
							
					
						MRC:
						The required current value,applied to the energizing element,at which the switching mechanism or actuator element must have assumed a fully operated position.CRPQ
					 
					
						Operating Current Rating And Type:
					
					
						65.0 milliamperes dc single winding					
				 
							
					
						MRC:
						The master requirement codes of those requirements which are technically critical by reason of tolerance,fit,performance,or other characteristics which affect identification of the item.CRTL
					 
					
						Criticality Code Justification:
					
					
						Feat					
				 
							
					
						MRC:
						The interval for which the item,by design,is purposely delayed between introduction of power into the energizing element and completion of travel of the contact carrier,and/or between interruption of the energizing power and return of the contact carrier to its normal de-energizing position.CRXH
					 
					
						Time Delay:
					
					
						0.006 seconds  fixed operate and release time					
				 
							
					
						MRC:
						The amount and type of voltage required at designated temperature to be applied to the input or energizing element of the item to ensure normal operation of the switching elements.CSXF
					 
					
						Operating Voltage Rating And Type At Specificationified Temp:
					
					
						28.0 volts dc 25 degrees celsius single winding					
				 
							
					
						MRC:
						The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.CTDL
					 
					
						Main Contact Load Current Rating At Maximum Rated Voltage:
					
					
						3.0 amperes ac inductive load and 3.0 amperes dc inductive load					
				 
							
					
						MRC:
						The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.CTDL
					 
					
						Main Contact Load Current Rating At Maximum Rated Voltage:
					
					
						5.0 amperes ac resistive load and 5.0 amperes dc resistive load					
				 
							
					
						MRC:
						The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.CTDL
					 
					
						Main Contact Load Current Rating At Maximum Rated Voltage:
					
					
						1.0 amperes ac lamp load and 1.0 amperes dc lamp load					
				 
							
					
						MRC:
						The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.CTDL
					 
					
						Main Contact Load Current Rating At Maximum Rated Voltage:
					
					
						2.0 amperes ac motor load and 2.0 amperes dc motor load					
				 
							
					
						MRC:
						The highest voltage at which the main contacts are rated for normal operation,expressed in volts.CWAB
					 
					
						Main Contact Maximum Voltage Rating In Volts:
					
					
						115.0 ac and 28.0 dc					
				 
							
					
						MRC:
						The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.TEST
					 
					
						Test Data Document:
					
					
						81349-mil-r-83536 specification specification (includes engineering type bulletins,  brochures, etc.,  that reflect specification type data in specification format;  excludes commercial catalogs,  industry directories,  and similar trade publications,  reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical",  "average",  "",  etc.).					
				 
							
					
						MRC:
						Indicates the type and number of terminals for providing electrical connection.TTQY
					 
					
						Terminal Type And Quantity:
					
					
						14 wire hook all functions					
				 
							
					
						MRC:
						The document designator of the specification or standard which established the item of supply.ZZZK
					 
					
						Specification Data:
					
					
						81349-mil-r-83536/5 government specification government specification