Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Informationen zum Teil
Cooling tower-not incl.; accessories-not incl.
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Air Conditioner
MRC:
Indicates the type of mount utilized to support the item.AAXX
Mounting Type:
Trailer
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
50.0 hertz
MRC:
Indicates the designed use of the item.ALCD
Usage Design:
Compressor, condenser, evaporator
MRC:
The value(s) of potential for which the item is rated.AMSE
Voltage Rating:
Between 220.0 volts and 440.0 volts
MRC:
Indicates the type of coolant used with the item.ARNA
Coolant Type:
Freon-12
MRC:
The source of power which drives the item.ATJK
Power Source:
Electric motor
MRC:
The number of electric motors provided.AWLX
Electric Motor Quantity:
3
MRC:
Indicates the type of cooling for which the condenser is designed.AZAD
Condenser Cooling Type:
Air
MRC:
A relative measurement of the mass of an item with respect to its density.AZQK
Weight:
7500.000 pounds
MRC:
Indicates the type of compressor unit for which the item is designed.AZSD
Compressor Unit Type:
Open
MRC:
The nominal capacity of the item to cool.AZSF
Cooling Capacity:
1000.0 cubic feet per minute
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Evaporative condenser
MRC:
The chemical compound or mechanical mixture properties of which the cabinet is fabricated.CYGG
Cabinet Material:
Aluminum-copper free or steel
MRC:
The capacity of the item to cool,expressed in british thermal units per hour.CYJE
Cooling Capacity In Btu Per Hour:
138000.0
MRC:
The number of alternating current phases.FAAZ
Phase:
Three