Teilenummer MEP-026B

Diesel Engine Generator Set

Preise und Verfügbarkeit

Reichen Sie dieses Formular ein, um die aktuellen Preise und die Verfügbarkeit dieser NSN zu erfahren.
Teilenummer:
Menge:
E-Mail-Adresse:
Telefon:
Referenz:
Firma:
Name:

Wir geben Ihre Daten nicht an Dritte weiter und verkaufen sie auch nicht.
Privatsphäre | Bedingungen

All major credit cards accepted as well as gov. p-cards
Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Teilenummer:
mep-026b
Entmilitarisierung:
No
Lagerfähigkeit:
Maßeinheit:
NIIN:
011500367
NSN
Nationale Bestandsnummer:
6115-01-150-0367 6115011500367
TXT
Beschreibung:
Diesel Engine Generator Set
INC
INC
Artikelname-Code:
00476
MRC:
The cooling medium used to maintain the required operating temperature of the prime mover.AAXS
Prime Mover Cooling Medium:
Air
MRC:
Indicates the type of mount utilized to support the item.AAXX
Mounting Type:
Skid
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
39.000 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
28.000 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
23.750 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Dc
MRC:
The direct current rating for which the item is rated,expressed in amperes.ACUT
Direct Current Rating In Amps:
0.25 and 0.77
MRC:
The value,or range of values,of direct current potential for which the item is rated.ACYR
Dc Voltage Rating:
28.0 volts
MRC:
The means of cooling used to maintain the required operating temperature of the item.AENK
Cooling Method:
Heat exchange
MRC:
An identifying number assigned by the government agency or commercial organization controlling the item.AMSB
Identifying Number:
Mep-026b type no.
MRC:
The name of the manufacturer.AQGA
Manufacturer Name:
Mobile electric power u s army materiel command
MRC:
The direct current for which the item is rated,expressed in watts.AYHA
Dc Wattage Rating:
3.0 kilowatts
MRC:
An indication of whether or not an excitor is included.AYHF
Excitor:
Included
MRC:
The means used to start the prime mover.AYQZ
Prime Mover Starting Method:
Electric motor
MRC:
The total electrical voltage required for cranking the item,expressed in volts.AYSA
Cranking Voltage In Volts:
24.0
MRC:
An indication of whether or not an automatic starting feature is provided.AZBM
Automatic Starting Feature:
Not provided
MRC:
The ambient temperature of the medium surrounding an item at which it can be operated,expressed in degrees celsius.AZCL
Ambient Tempurature In Deg Celsius:
-31.7 and 51.7
MRC:
The permissible temperature increase for continuous operation,at which the item is rated,expressed in degrees celsius.AZCM
Tempurature Rise Rating In Deg Celsius For Continuous Operation:
75.0