Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
					
					
					
					
						Maßeinheit:
						* special requirements. EA					
 
					
				 
			 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Electric Water Heater				
			 
			
										
					
						MRC:
						The maximum pressure at which an item is designed to operate.AAJJ
					 
					
						Maximum Operating Pressure:
					
					
						110.0 pounds per square inch					
				 
							
					
						MRC:
						Consists of plating,dip,and/or coating that cannot be wiped off. plating and/or coating is any chemical and/or metallic additive,electrochemical,or mild mechanical process which protects the outside surface.AAJP
					 
					
						Outside Surface Treatment:
					
					
						Painted					
				 
							
					
						MRC:
						Indicates the type of heating unit which imparts heat.ABAL
					 
					
						Heating Element Type:
					
					
						Any acceptable					
				 
							
					
						MRC:
						The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
					 
					
						Overall Length:
					
					
						72.750 inches 					
				 
							
					
						MRC:
						A measurement of the longest straight line across a circular cross-sectional plane.ADAV
					 
					
						Overall Diameter:
					
					
						36.000 inches 					
				 
							
					
						MRC:
						An indication of whether or not an insulated feature is included.AHGR
					 
					
						Insulated Feature:
					
					
						Not included					
				 
							
					
						MRC:
						The name and number of those parts furnished with the item of supply that have not been specified elsewhere.AKYN
					 
					
						Furnished Items And Quantity:
					
					
						Relief valve 1					
				 
							
					
						MRC:
						An indication of whether or not an attachment device is included.ALHG
					 
					
						Attachment Device:
					
					
						Included					
				 
							
					
						MRC:
						The rated heating capacity of the item per hour.AMHR
					 
					
						Heating Capacity Per Hour:
					
					
						306.0 gallons					
				 
							
					
						MRC:
						The number of degrees the temperature rises per hour.AMHX
					 
					
						Tempurature Rise Per Hour:
					
					
						90.0 degrees fahrenheit					
				 
							
					
						MRC:
						An indication of whether or not a thermostatic switch is included.AMJX
					 
					
						Thermostatic Switch:
					
					
						Included					
				 
							
					
						MRC:
						Indicates the capacity of the tank.AMKA
					 
					
						Tank Capacity:
					
					
						306.0 gallons					
				 
							
					
						MRC:
						Designates the thread diameter,series/type,and number of threads per measurement scale of the water inlet connection.AMLL
					 
					
						Water Inlet Connection Thread Size And Series/type Designator:
					
					
						1-11-1/2 npt					
				 
							
					
						MRC:
						Designates the thread diameter,series/type,and number of threads per measurement scale of the water outlet connection.AMLM
					 
					
						Water Outlet Connection Thread Size And Series/type Designator:
					
					
						1-11-1/2 npt					
				 
							
					
						MRC:
						The number of water inlet connections.AMLQ
					 
					
						Water Inlet Connection Quantity:
					
					
						1					
				 
							
					
						MRC:
						The number of water outlet connections.AMLR
					 
					
						Water Outlet Connection Quantity:
					
					
						1					
				 
							
					
						MRC:
						The number of alternating current phases.FAAZ
					 
					
						Phase:
					
					
						Three					
				 
							
					
						MRC:
						The cycles per second /hertz/ of the alternating current.FREQ
					 
					
						Frequency In Hertz:
					
					
						60.0					
				 
							
					
						MRC:
						The element,compound,or mixture of which an item is fabricated,excluding any surface treatment.MATL
					 
					
						Material:
					
					
						Copper alloy					
				 
							
					
						MRC:
						The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
					 
					
						Material:
					
					
						Copper alloy					
				 
							
					
						MRC:
						The document designator of the specification or standard which established the item of supply.ZZZK
					 
					
						Specification Data:
					
					
						81349-mil-h-965d amend2 government specification