Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Teilenummer:
mil-hdbk-300pme
Entmilitarisierung:
Yes - DEMIL/MLI
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Signal Generator
MRC:
Indicates the type of mount utilized to support the item.AAXX
Mounting Type:
Portable
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
11.500 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
5.250 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
7.750 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
Between 50.0 hertz and 400.0 hertz
MRC:
The range of complete cyclic changes,per unit of time,for which an item is rated.AFGQ
Frequency Range Rating:
+0.000/+1.000 megahertz
MRC:
The name assigned to the item by the joint electronics type designation system.AKWA
Joint Electronics Type Designation System Item Name:
Generator, waveform
MRC:
The type number assigned to the item by the joint electronics type designation system.AKWB
Joint Electronics Type Designation System Item Type Number:
An/usm-351
MRC:
An indication of whether or not a facility/ies/ to accommodate a battery/ies/ is included.ALSF
Internal Battery Accommodation:
Not included
MRC:
The total opposition (resistive and reactive) presented by the item to an alternating current load.AMNE
Output Impedance Rating:
600.0 ohms and 50.0 ohms
MRC:
The value(s) of potential for which the item is rated.AMSE
Voltage Rating:
Between 105.0 volts and 125.0 volts
MRC:
An indication of the maximum signal output transmitted by the item.BHGB
Maximum Signal Output:
0 to 30 vpp into 600 ohms, 10 vpp into 50 ohms, 5 vpp into open circuit
MRC:
The number of alternating current phases.FAAZ
Phase:
Single