Teilenummer:
mil-hdbk-300pme
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Oscilloscope
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
19.500 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
13.250 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
19.313 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
60.0 hertz
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Type no. Oa-283/gpn
MRC:
The name and number of parts supplied with the item which may be required for application.AKYD
Accessory Components And Quantity:
Cables, test 13; calibration screen 1
MRC:
The value(s) of potential for which the item is rated.AMSE
Voltage Rating:
115.0 volts
MRC:
The number of beams provided on the item.ATES
Beam Quantity:
1
MRC:
The means of attaching the item.AXGY
Mounting Method:
Rack
MRC:
Designates the relative or proportionate dimensions of the screen.BGQK
Screen Size:
5 in.
MRC:
An indication of whether or not an expanded sweep is provided.BGSD
Expanded Sweep:
Not provided
MRC:
An indication of whether or not provisions for rating the deflection sensitivity through the amplifier are provided.BHDD
Amplifier Deflection Sensitivity Provision:
Provided
MRC:
The value,or range of values,for which the vertical deflection sensitivity is rated.BHDF
Vertical Deflection Sensitivity Voltage Rating:
300.0 millivolts peak to peak per inch
MRC:
The value,or range of values,for which the horizontal deflection sensitivity is rated.BHDG
Horizontal Deflection Sensitivity Voltage Rating:
400.0 millivolts any acceptable major
MRC:
An indication of whether or not an input intensity modulation feature is provided.BHDH
Input Intensity Modulation Feature:
Not provided
MRC:
An indication of whether or not provisions for rating the direct connection to the plate deflection sensitivity is provided.BHDL
Plate Direct Connection Deflection Sensitivity Provision:
Provided
MRC:
The value,or range of values,at which the vertical deflection for direct connection is rated to respond.BHDM
Direct Connection Vertical Deflection Sensitivity Voltage Rating:
84.0 volts any acceptable outside diameter
MRC:
The value,or range of values,at which the horizontal deflection for direct connection is rated to respond.BHDN
Direct Connection Horizontal Deflection Sensitivity Voltage Rating:
100.0 volts rms per inch
MRC:
An indication of whether or not a frequency response rating is provided.BHDP
Frequency Response Rating:
Provided
MRC:
The minimum and maximum frequencies to which the x-axis will respond.BHDQ
X-axis Frequency Response Rating:
Between 0.0 hertz and 200000.0 hertz
MRC:
The minimum and maximum frequencies to which the y-axis will respond.BHDR
Y-axis Frequency Response Rating:
Between 30.0 hertz and 9000000.0 hertz
MRC:
An indication of whether or not amplifier input impedance rating is provided.BHDT
Amplifier Input Impedance Rating Provision:
Not provided
MRC:
The total opposition (resistive and reactive) which the item offers to the x-axis input flow of alternating current.BHDW
X-axis Input Impedance Rating:
100.0 kilohms
MRC:
The total opposition (resistive and reactive) which the item offers to the y-axis input flow of alternating current.BHDX
Y-axis Input Impedance Rating:
2.0 megohms
MRC:
The total opposition (resistive and reactive) which the item offers to the z-axis input flow of alternating current.BHDY
Z-axis Input Impedance Rating:
100.0 kilohms
MRC:
An indication of whether or not a calibrated screen scale is included.BHFF
Calibrated Screen Scale:
Not included
MRC:
An indication of whether or not a trace storage tube is included.BHFH
Trace Storage Tube:
Not included
MRC:
An indication of whether or not camera recording device accommodations are provided.BHFT
Camera Recording Device Accommodation:
Not provided
MRC:
The number of alternating current phases.FAAZ
Phase: