Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Entmilitarisierung:
Yes - DEMIL/MLI
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Oscilloscope
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
16.938 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
7.828 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
12.812 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
Between 60.0 hertz and 400.0 hertz
MRC:
The value(s) of potential for which the item is rated.AMSE
Voltage Rating:
115.0 volts
MRC:
The number of beams provided on the item.ATES
Beam Quantity:
1
MRC:
The acceptable limits of deviation from the designed standard output value of the item,expressed in percent.BDJD
Accuracy Range In Percent:
-3.0/+3.0
MRC:
The acceptable limits of deviation from the designed standard output value of the item,expressed in percent.BDJD
Accuracy Range In Percent:
-3.0 to 3.0
MRC:
Designates the relative or proportionate dimensions of the screen.BGQK
Screen Size:
4.000 in.
MRC:
An indication of whether or not sweep circuits are included.BGQL
Sweep Circuits:
Included
MRC:
An indication of whether or not a generator driven feature is included.BGQM
Generator Driven Feature:
Included
MRC:
Indicates the type of sweep circuits provided.BGQN
Sweep Circuit Type:
Horizontal
MRC:
The range of complete cyclic changes,per unit of time,for which the sweep is rated.BGQP
Sweep Frequency Range:
+0.0/+50.0 megahertz
MRC:
The range of complete cyclic changes,per unit of time,for which the sweep is rated.BGQP
Sweep Frequency Range:
+0.0 to 50.0 megahertz
MRC:
The length of time consumed by a single trigger sweep.BGQQ
Single Trigger Sweep Duration:
Between 0.5 microseconds and 10.0 seconds
MRC:
The maximum absolute value for which the trigger sweep voltage is rated.BGRZ
Trigger Sweep Voltage Amplitude Rating:
100.0 millivolts and 200.0 millivolts
MRC:
An indication of whether or not a trigger sweep polarity switch is included.BGSB
Trigger Sweep Polarity Switch:
Included
MRC:
The distance between indicated pulse intervals shown on the screen of a trigger sweep designed item.BGSC
Trigger Sweep Marker Intervals:
6 by 10 division internal graticule; 1 division equals 1 centimeter; 0.2 subdivision markings on major horizontal & vertical axes
MRC:
An indication of whether or not an expanded sweep is provided.BGSD
Expanded Sweep:
Provided
MRC:
An indication of whether or not provisions for rating the deflection sensitivity through the amplifier are provided.BHDD
Amplifier Deflection Sensitivity Provision:
Provided
MRC:
The value,or range of values,for which the vertical deflection sensitivity is rated.BHDF
Vertical Deflection Sensitivity Voltage Rating:
0.005 volts rms per centimeter and 20.000 volts rms per centimeter
MRC:
The value,or range of values,for which the horizontal deflection sensitivity is rated.BHDG
Horizontal Deflection Sensitivity Voltage Rating:
0.1 volts cw minor and 10.0 volts peak minor
MRC:
An indication of whether or not an input intensity modulation feature is provided.BHDH
Input Intensity Modulation Feature:
Provided
MRC:
The value,or range of values,at which the visual modulation sensitivity is rated to respond.BHDJ
Visual Modulation Sensitivity Voltage Rating:
5.0 volts
MRC:
An indication of whether or not provisions for rating the direct connection to the plate deflection sensitivity is provided.BHDL
Plate Direct Connection Deflection Sensitivity Provision:
Not provided
MRC:
An indication of whether or not a frequency response rating is provided.BHDP
Frequency Response Rating:
Provided
MRC:
The minimum and maximum frequencies to which the x-axis will respond.BHDQ
X-axis Frequency Response Rating:
2.0 megahertz
MRC:
The minimum and maximum frequencies to which the y-axis will respond.BHDR
Y-axis Frequency Response Rating:
50.0 megahertz
MRC:
An indication of whether or not amplifier input impedance rating is provided.BHDT
Amplifier Input Impedance Rating Provision:
Provided
MRC:
The total opposition (resistive and reactive) which the item offers to the x-axis input flow of alternating current.BHDW
X-axis Input Impedance Rating:
1.0 megohms
MRC:
The total opposition (resistive and reactive) which the item offers to the y-axis input flow of alternating current.BHDX
Y-axis Input Impedance Rating:
1.0 megohms
MRC:
An indication of the shape of the amplitude calibrating voltage waveform.BHDZ
Amplitude Calibrating Voltage Waveform:
Square wave
MRC:
The peak to peak value for which the item is calibrated.BHFB
Calibrating Peak To Peak Amplitude:
1.0 volts
MRC:
The number of measurement ranges included.BHFC
Measurement Range Quantity:
11
MRC:
An indication of whether or not a calibrated screen scale is included.BHFF
Calibrated Screen Scale:
Not included
MRC:
An indication of whether or not a trace storage tube is included.BHFH
Trace Storage Tube:
Not included
MRC:
An indication of the function of the plug in units and the number provided.BHFS
Plug In Unit Function And Quantity:
Horizontal and vertical amplifiers 2
MRC:
An indication of whether or not camera recording device accommodations are provided.BHFT
Camera Recording Device Accommodation:
Provided
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
Literature and references available for information pertaining to the item.RDAL
Reference Data And Literature:
To 33a1-13-432-1