Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Capillary Indicating Thermometer
MRC:
The length of a straight line which passes through the center of a case,and terminates at the circumference.ABKJ
Case Diameter:
9.906 inches
MRC:
The length of a straight line which passes through the center of an unthreaded mounting hole,and terminates at the circumference.AEBV
Unthreaded Mounting Hole Diameter:
0.250 inches
MRC:
The length of a straight line which passes through the center of a mounting bolt circle,and terminates at the circumference.AFFL
Mounting Bolt Circle Diameter:
9.625 inches
MRC:
The length of a straight line which passes through the center of the dial,and terminates at the circumference.ASSP
Dial Diameter:
8.500 inches
MRC:
Indicates the type of scale.ATEQ
Scale Type:
Concentric dial
MRC:
The smallest value between the markings on a scale.AWAG
Scale Smallest Increment:
10.0 degrees fahrenheit
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
1 flush and 3 hole
MRC:
The hue or tint of the inscription(s) and/or that portion of the scale which surrounds the inscription on the scale.BGKZ
Scale Inscription/background Color:
Black marking on yellow background
MRC:
Indicates the type of case provided.BHMC
Case Type:
Dustproof
MRC:
An indication of the medium used to actuate the item.BKCM
Actuating Medium:
Gas
MRC:
The amount of accuracy for which the scale is rated.BKCN
Scale Accuracy Rating:
0.8 pct entire range
MRC:
The number of bulbs provided.BKCT
Bulb Quantity:
1
MRC:
Indicates the type of bulb provided with the item.BKCW
Bulb Type:
Flexible extension plain
MRC:
Indicates the type of bulb connection provided with the item.BKCX
Bulb Connection Type:
Threaded
MRC:
A measurement of the longest dimension of the active portion of an item,in distinction from width.BKCY
Active Portion Length:
3.500 inches
MRC:
The length of a straight line which passes through the center of the active portion of a circular figure or body,and terminates at the circumference.BKCZ
Active Portion Diameter:
0.375 inches
MRC:
The means used to connect the indicator.BLQF
Indicator Connection Method:
Flexible tube
MRC:
A measurement of the longest dimension of the flexible tube,in distinction from width.BLQG
Flexible Tube Length:
60.000 inches
MRC:
The minimum and maximum numeric values representing the type of scale measurement.CSYG
Scale Measurement Range:
+400.000/+1200.000 degrees fahrenheit
MRC:
The minimum and maximum numeric values representing the type of scale measurement.CSYG
Scale Measurement Range:
+400.000 to 1200.000 degrees fahrenheit
Bulblength:
21.500 inches
MRC:
Indicates the type and number of pointer(s) or pen(s).CSYJ
Pointer/pen Type And Quantity:
1 indicating single and 1 reference single
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Plastic meter case
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Stainless steel bulb