Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
			 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Reciprocating Compressor Unit				
			 
			
										
					
						MRC:
						The number of compressors incorporated in the unit.AAXG
					 
					
						Compressor Quantity:
					
					
						1					
				 
							
					
						MRC:
						The percentage of time for which the item is designed to generate without degradation of rated capacity and discharge pressure.AAXJ
					 
					
						Duty Cycle In Percent:
					
					
						100					
				 
							
					
						MRC:
						The media the machine is designed to compress.AAXK
					 
					
						Gas For Which Designed:
					
					
						Air					
				 
							
					
						MRC:
						The rated capacity of gas delivered by the last stage of compression.AAXL
					 
					
						Discharge Flow Rate:
					
					
						15.000 cubic feet per minute					
				 
							
					
						MRC:
						The gage pressure of gas delivered by the last stage of compression.  referred to as condensing pressure for refrigeration compressors.AAXM
					 
					
						Discharge Pressure:
					
					
						3500.000 pounds per square inch gage					
				 
							
					
						MRC:
						The design of the system necessary to maintain the required operating temperature of an item and discharge temperature of the compressed gases.AAXP
					 
					
						Cooling System Design:
					
					
						Single					
				 
							
					
						MRC:
						The cooling medium used to maintain the required operating temperature of the compressed gases.AAXQ
					 
					
						Compressed Gas Cooling Medium:
					
					
						Air					
				 
							
					
						MRC:
						The cooling medium used to maintain the required operating temperature of the compressor.AAXR
					 
					
						Compressor Cooling Medium:
					
					
						Air					
				 
							
					
						MRC:
						The cooling medium used to maintain the required operating temperature of the prime mover.AAXS
					 
					
						Prime Mover Cooling Medium:
					
					
						Air					
				 
							
					
						MRC:
						The position of the gas cooling equipment whether between stages /intercooler/,after the last stage /aftercooler/,or both.AAXU
					 
					
						Gas Cooling Equipment Type:
					
					
						Air type aftercooler and air type intercooler					
				 
							
					
						MRC:
						The method by which a no load condition is obtained for starting the item.AAXV
					 
					
						Unloader Type:
					
					
						Automatic					
				 
							
					
						MRC:
						Indicates the type of mount utilized to support the item.AAXX
					 
					
						Mounting Type:
					
					
						Wheel					
				 
							
					
						MRC:
						The reciprocating compressor design as determined by the mechanical action by which compression takes place in the cylinder/s/ of the compressor.AAXY
					 
					
						Reciprocating Compressor Design:
					
					
						Single acting					
				 
							
					
						MRC:
						The number of intake connections included on the item.AAYT
					 
					
						Intake Connection Quantity:
					
					
						1					
				 
							
					
						MRC:
						Indicates the type of prime mover included with the unit.AKDJ
					 
					
						Prime Mover Type:
					
					
						Electric motor					
				 
							
					
						MRC:
						Indicates the type of control device provided.BDML
					 
					
						Control Device Type:
					
					
						Automatic start-stop and constant speed					
				 
							
					
						MRC:
						Indicates the type of safety device(s) provided.BPRZ
					 
					
						Safety Device Type:
					
					
						Relief valve					
				 
							
					
						MRC:
						Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
					 
					
						Features Provided:
					
					
						Fungus resistant treatment					
				 
							
					
						MRC:
						Indicates the type and amount of electrical flow at which the item is designed to operate,expressed in amperes.CQJY
					 
					
						Current Type And Rating In Amps:
					
					
						20.0 ac and 40.0 ac					
				 
							
					
						MRC:
						The total electrical voltage,expressed in volts,and the type of current whether alternating or direct.CSBH
					 
					
						Voltage In Volts And Current Type:
					
					
						208.0 ac or 416.0 ac					
				 
							
					
						MRC:
						The number of alternating current phases.FAAZ
					 
					
						Phase:
					
					
						Three					
				 
							
					
						MRC:
						The cycles per second /hertz/ of the alternating current.FREQ
					 
					
						Frequency In Hertz:
					
					
						60.0					
				 
							
					
						MRC:
						The number,letter,or symbol that indicates the type,style,grade,class,and the like,of an item in a nonidentifying specification or standard.ZZZT
					 
					
						Specification Or Standard:
					
					
						2 type and 2 class