Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Gasoline Engine Generator Set
MRC:
The cooling medium used to maintain the required operating temperature of the prime mover.AAXS
Prime Mover Cooling Medium:
Air
MRC:
Indicates the type of mount utilized to support the item.AAXX
Mounting Type:
Skid shock tubular frame
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
39.656 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
25.000 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
30.000 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
60.0 hertz and 60.0 hertz
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Generator sets/pwr equip 60hz 5-10kw
MRC:
An indication of whether or not winterization is included.AMWJ
Winterization Feature:
Not included
MRC:
The alternating current for which the item is rated,expressed in watts.AYGY
Ac Wattage Rating:
5.0 kilowatts and 5.0 kilowatts
MRC:
The total electrical line to line voltage for which the item is rated,expressed in volts.AYHB
Line To Line Voltage In Volts:
120.0 and 240.0 and 120.0 and 208.0
MRC:
The total electrical line to neutral voltage for which the item is rated,expressed in volts.AYHC
Line To Neutral Voltage In Volts:
120.0
MRC:
The ratio between actual rated power,and power required by a specified load applied to the item,expressed in percent.AYHD
Power Factor In Percent:
80.0
MRC:
Indicates the type of excitor provided.AYHE
Excitor Type:
Self-excited
MRC:
The means used to start the prime mover.AYQZ
Prime Mover Starting Method:
Manually by rope
MRC:
An indication of whether or not an automatic starting feature is provided.AZBM
Automatic Starting Feature:
Not provided
MRC:
Indicates the type of housing provided.AZCB
Housing Type:
Open
MRC:
The ambient temperature of the medium surrounding an item at which it can be operated,expressed in degrees celsius.AZCL
Ambient Tempurature In Deg Celsius:
-31.7 and 51.7
MRC:
The permissible temperature increase for continuous operation,at which the item is rated,expressed in degrees celsius.AZCM
Tempurature Rise Rating In Deg Celsius For Continuous Operation:
75.0
MRC:
An indication of whether or not radio interference suppression is included.AZKT
Radio Interference Suppression:
Included
MRC:
The number of alternating current phases.FAAZ
Phase:
Single or three
MRC:
The number,letter,or symbol that indicates the type,style,grade,class,and the like,of an item in a nonidentifying specification or standard.ZZZT
Specification Or Standard:
2 type and 2 class