Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Block Ice Making Plant
MRC:
Indicates the type of unit.APQB
Unit Type:
Self-contained
MRC:
Indicates the type of coolant used with the item.ARNA
Coolant Type:
Freon-12
MRC:
The source of power which drives the item.ATJK
Power Source:
Gasoline engine
MRC:
Indicates the type of cooling for which the condenser is designed.AZAD
Condenser Cooling Type:
Air
MRC:
The rated horsepower of the engine.AZBH
Err Default:
Err default
MRC:
The rated horsepower of the engine.AZBH
Engine Horsepower Rating:
12.500
MRC:
An indication of whether or not a secondary refrigerant is included.AZDJ
Err Default:
Err default
MRC:
An indication of whether or not a secondary refrigerant is included.AZDJ
Secondary Refrigerant:
Included
MRC:
An indication of whether or not a cooling tower is included.AZDN
Err Default:
Err default
MRC:
An indication of whether or not a cooling tower is included.AZDN
Cooling Tower:
Not included
MRC:
Indicates the type of compressor provided.AZLA
Compressor Type:
Reciprocating
MRC:
The amount of ice the item can produce in a 24 hour period.AZLH
Ice Capacity Per 24 Hour Period:
1.0 tons
MRC:
The number of cans the freezer tank will accommodate.AZLJ
Err Default:
Err default
MRC:
The number of cans the freezer tank will accommodate.AZLJ
Freezer Tank Can Quantity Accommodated:
20
MRC:
The outside measurement from the bottom to the top of the freezer tank,in distinction from depth.AZLK
Err Default:
Err default
MRC:
The outside measurement from the bottom to the top of the freezer tank,in distinction from depth.AZLK
Freezer Tank Outside Height:
3.667 feet
MRC:
The outside measurement of the longest dimension of the freezer tank,in distinction from width.AZLL
Err Default:
Err default
MRC:
The outside measurement of the longest dimension of the freezer tank,in distinction from width.AZLL
Freezer Tank Outside Length:
8.333 feet
MRC:
The outside measurement taken at right angles to the length of the freezer tank,in distinction from thickness.AZLM
Err Default:
Err default
MRC:
The outside measurement taken at right angles to the length of the freezer tank,in distinction from thickness.AZLM
Freezer Tank Outside Width:
4.167 feet
MRC:
An indication of whether or not a freezing tank low pressure water agitating system is included.AZLN
Err Default:
Err default
MRC:
An indication of whether or not a freezing tank low pressure water agitating system is included.AZLN
Freezing Tank Low Pressure Water Agitating System:
Not included
MRC:
An indication of whether or not a freezing tank brine agitator is included.AZLP
Err Default:
Err default
MRC:
An indication of whether or not a freezing tank brine agitator is included.AZLP
Freezing Tank Brine Agitator:
Included
MRC:
The inside measurement of the longest dimension of the can top,in distinction from width.AZLQ
Err Default:
Err default
MRC:
The inside measurement of the longest dimension of the can top,in distinction from width.AZLQ
Can Top Inside Length:
14.000 inches
MRC:
The inside measurement taken at right angles to the length of the can top,in distinction from thickness.AZLR
Err Default:
Err default
MRC:
The inside measurement taken at right angles to the length of the can top,in distinction from thickness.AZLR
Can Top Inside Width:
5.000 inches
MRC:
The inside measurement between specified points of a can,in distinction from height.AZLS
Err Default:
Err default
MRC:
The inside measurement between specified points of a can,in distinction from height.AZLS
Can Inside Depth:
32.000 inches
MRC:
An indication of whether or not the ice can is provided with a high pressure air restriction conveyance.AZLT
Err Default:
Err default
MRC:
An indication of whether or not the ice can is provided with a high pressure air restriction conveyance.AZLT
Ice Can High Pressure Air Restriction Conveyance:
Not provided
MRC:
An indication of whether or not an evaporative condenser is included.AZLW
Err Default:
Err default
MRC:
An indication of whether or not an evaporative condenser is included.AZLW
Evaporative Condenser:
Not included
MRC:
An indication of whether or not a precooling tank(s) is included.AZLX
Err Default:
Err default
MRC:
An indication of whether or not a precooling tank(s) is included.AZLX
Precooling Tank:
Not included
MRC:
The amount of ice each can will hold.BBLP
Err Default:
Err default
MRC:
The amount of ice each can will hold.BBLP
Ice Capacity Per Can:
50.0 pounds