Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
			 
							
					
						Informationen zum Teil
						Cannula extends 4.500 in.Beyond the end of hub, 20 mm lg specimen retaining notch, disposable, unit q type 1
					 
				 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Biopsy Needle				
			 
			
										
					
						MRC:
						An indication of whether or not the item is free of living organisms.AKMX
					 
					
						Sterility:
					
					
						Sterile					
				 
							
					
						MRC:
						The designation derived from the name of the designer or use for which the item is intended.ANEH
					 
					
						Design Designation:
					
					
						Prostatic					
				 
							
					
						MRC:
						The designation of the wall thickness of the cannula.ANNN
					 
					
						Cannula Wall Thickness Designation:
					
					
						Regular					
				 
							
					
						MRC:
						The element,compound,or mixture of which the item is fabricated,excluding any surface treatment,and its location.ANNQ
					 
					
						Material And Location:
					
					
						Plastic hub err-100 err-100					
				 
							
					
						MRC:
						The element,compound,or mixture of which the item is fabricated,excluding any surface treatment,and its location.ANNQ
					 
					
						Material And Location:
					
					
						Plastic obturator knob err-100 err-100					
				 
							
					
						MRC:
						The element,compound,or mixture of which the item is fabricated,excluding any surface treatment,and its location.ANNQ
					 
					
						Material And Location:
					
					
						Plastic sheath err-100 err-100					
				 
							
					
						MRC:
						The element,compound,or mixture of which the item is fabricated,excluding any surface treatment,and its location.ANNQ
					 
					
						Material And Location:
					
					
						Steel,  federal standard 66,  aisi 304/sae 30304 cannula err-100 err-100					
				 
							
					
						MRC:
						The element,compound,or mixture of which the item is fabricated,excluding any surface treatment,and its location.ANNQ
					 
					
						Material And Location:
					
					
						Steel,  federal standard 66,  aisi 304/sae 30304 obturator rod err-100 err-100					
				 
							
					
						MRC:
						The element,compound,or mixture of which the item is fabricated,excluding any surface treatment,and its location.ANNQ
					 
					
						Material And Location:
					
					
						Plastic hub					
				 
							
					
						MRC:
						The element,compound,or mixture of which the item is fabricated,excluding any surface treatment,and its location.ANNQ
					 
					
						Material And Location:
					
					
						Plastic obturator knob					
				 
							
					
						MRC:
						The element,compound,or mixture of which the item is fabricated,excluding any surface treatment,and its location.ANNQ
					 
					
						Material And Location:
					
					
						Plastic sheath					
				 
							
					
						MRC:
						The element,compound,or mixture of which the item is fabricated,excluding any surface treatment,and its location.ANNQ
					 
					
						Material And Location:
					
					
						Steel,  federal standard 66,  aisi 304/sae 30304 obturator rod					
				 
							
					
						MRC:
						The element,compound,or mixture of which the item is fabricated,excluding any surface treatment,and its location.ANNQ
					 
					
						Material And Location:
					
					
						Steel,  federal standard 66,  aisi 304/sae 30304 cannula					
				 
							
					
						MRC:
						A universal standard stubs needle gage designation representing the outside diameter of the needle cannula and its location on the item.ANNS
					 
					
						Needle Cannula Gage Designation And Location:
					
					
						14 gage cannula					
				 
							
					
						MRC:
						An indication of whether or not a security stop is included.ASWZ
					 
					
						Security Stop:
					
					
						Not included					
				 
							
					
						MRC:
						Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
					 
					
						Features Provided:
					
					
						Sterile					
				 
							
					
						MRC:
						The measured weight of the exterior container.ECWT
					 
					
						Exterior Container Weight:
					
					
						3.00 pounds					
				 
							
					
						MRC:
						A measurement of volume taken by multiplying the length by the width by the height of the exterior container and rendered in cubic units.EXME
					 
					
						Exterior Container Cubic Measure:
					
					
						2.001 cubic feet					
				 
							
					
						MRC:
						The number of units of issue placed inside the exterior container.EXQT
					 
					
						Exterior Container Quantity:
					
					
						72					
				 
							
					
						MRC:
						The number of wraps,boxes,or bundles,which contains two or more units of issue,placed inside an exterior container.PKQT
					 
					
						Intermediate Package Quantity:
					
					
						12					
				 
							
					
						MRC:
						A measurement of volume taken by multiplying the length by the width by the height of the unit of issue and rendered in cubic units.SUCB
					 
					
						Unit Of Issue Cube:
					
					
						0.019 cubic feet					
				 
							
					
						MRC:
						The measured weight of the actual container(s) or supporting device(s) which is in direct contact with the item and its contents.SUWT
					 
					
						Unit Of Issue Weight:
					
					
						0.13 pounds					
				 
							
					
						MRC:
						The number,letter,or symbol that indicates the type,style,grade,class,and the like,of an item in a nonidentifying specification or standard.ZZZT
					 
					
						Specification Or Standard:
					
					
						1 size