Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Informationen zum Teil
0.40 cfm, 1275.0 rpm at 110vac/50hz rating
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Reciprocating Vacuum Pump Unit
MRC:
The power required to start and operate the item at the actual rated capacity,including all accessories.AAXW
Brake Horsepower Required:
0.0625
MRC:
Indicates the type of mount utilized to support the item.AAXX
Mounting Type:
Base
MRC:
The number of stages incorporated in the item.AAYD
Stage Quantity:
1
MRC:
The number of discharge connections included on the item.AAYV
Discharge Connection Quantity:
1
MRC:
Indicates the type of discharge connection included on the item.AAYW
Discharge Connection Type:
Threaded internal
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
7.030 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
4.720 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
4.280 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The cooling medium used to maintain the required operating temperature of the item.ACZV
Cooling Medium:
Air
MRC:
The ultimate maximum vacuum,expressed in terms of absolute pressure,that may be produced by or applied to an item.ADLE
Vacuum Rating:
24.0 inches of mercury
MRC:
The number of pumps incorporated in the item.AENC
Pump Quantity:
1
MRC:
The specific gas with which the item is designed to be used.AENF
Specific Gas For Which Designed:
Air
MRC:
Indicates the type of pumping element included on the item.AENG
Pumping Element Type:
Diaphragm
MRC:
The speed of the drive shaft required to produce the rated capacity of an item,expressed in revolutions per minute.AEQC
Operating Speed At Rated Capacity In Rpm:
1275.0 and 1575.0
MRC:
The volume of air passed per unit of time through an item.AEQH
Air Displacement Rate:
0.49 cubic feet per minute in free air
MRC:
Indicates the type of prime mover included with the unit.AKDJ
Prime Mover Type:
Electric motor
MRC:
The electrical current rating,expressed in amperes.AMPS
Current Rating In Amps:
0.4
MRC:
Designates the thread diameter,series/type,and number of threads per measurement scale of the discharge connection.ASAZ
Discharge Connection Thread Size And Series/type Designator:
0.250-18 npt
MRC:
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.CXDH
Err Default:
Err default
MRC:
Designates the thread diameter and number of threads per measurement scale of the discharge connection.CXDR
Err Default:
Err default
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
110.0 and 115.0
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
50.0 and 60.0