Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Entmilitarisierung:
Yes - DEMIL/MLI
Informationen zum Teil
Regulated output; overvoltage and short circuit protection
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Power Supply
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
10.625 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
6.312 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
6.937 inches
MRC:
The relationship of the electrical power source to the item.AKWC
Electrical Power Source Relationship:
Operating
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
103.5 ac volts single operating power rqmt and 126.5 ac volts single operating power rqmt
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
17.0 dc volts single power output and 18.0 dc volts single power output
MRC:
The ambient temperature range at which the item is designed to operate.AYNH
Operating Ambient Tempurature Range:
-40.0/+75.0 degrees celsius
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
8.0 dc amperes single power output