Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Time Totalizing Meter
MRC:
The number of terminals for providing electrical connection to the item.AARA
Terminal Quantity:
2
MRC:
Indicates the type of terminals for providing electrical connection to the item.AARB
Terminal Type:
Solder
MRC:
Indicates the type of mount utilized to support the item.AAXX
Mounting Type:
Panel
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
Between 0.995 inches and 1.025 inches
MRC:
A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
Body Width:
Between 0.285 inches and 0.315 inches
MRC:
A measurement taken at right angles to the length of a mounting flange,in distinction from thickness.ADMH
Mounting Flange Width:
Between 0.345 inches and 0.375 inches
MRC:
The element,compound,or mixture of which the case is fabricated,excluding any surface treatment.ADTV
Case Material:
Any acceptable
MRC:
The hue or tint of the inscription on the item.AETS
Inscription Color:
White
MRC:
The hue or tint of the light emitted from that portion of the item which surrounds the inscription on the item.AETT
Inscription Background Color:
Black
MRC:
A measurement from the bottom to the top of a flange,in distinction from depth.AHGD
Flange Height:
Between 1.425 inches and 1.455 inches
MRC:
The pattern or arrangement that describes the mounting configuration of the item.ALGC
Mounting Configuration:
Two 0.125 in. Diameter countersunk mtg holes spaced 1.219 in. C to c
MRC:
Indicates the type of device used to register the condition(s).AMKD
Indicator Type:
Scale
MRC:
The value(s) of potential for which the item is rated.AMSE
Voltage Rating:
115.0 volts
MRC:
Indicates the type of unit.APQB
Unit Type:
Mounted
MRC:
An indication of the scale range.APSK
Scale Range:
+0.0/+1000.0 hour
MRC:
An indication of the scale range.APSK
Scale Range:
+0.0 to 1000.0 hour
MRC:
The frequency at which the item functions.APTT
Operating Frequency:
Between 50.0 hertz and 2400.0 hertz
MRC:
An indication of whether or not a hermetic protection is provided.AQCS
Hermetic Protection:
Not provided
MRC:
Indicates the type of movement provided.AQEC
Movement Type:
Electro-chemical
MRC:
A measurement between specified points on a body in distinction from height.ARBR
Body Depth:
Between 0.185 inches and 0.215 inches
MRC:
The smallest value between the markings on a scale.AWAG
Scale Smallest Increment:
50.00 hours
MRC:
The means of attaching the item.AXGY
Mounting Method:
Flush
MRC:
An indication of whether or not the item is provided with a reset feature.BHCH
Reset Feature:
Not provided
MRC:
Indicates the type of electrical movement provided.BHLR
Electrical Movement Type:
Electrochemical