Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
			 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Centrifugal Pump				
			 
			
										
					
						MRC:
						The number of intake connections included on the item.AAYT
					 
					
						Intake Connection Quantity:
					
					
						1					
				 
							
					
						MRC:
						The number of discharge connections included on the item.AAYV
					 
					
						Discharge Connection Quantity:
					
					
						1					
				 
							
					
						MRC:
						The type of service with which the item is designed to be used.ACKL
					 
					
						Media For Which Designed:
					
					
						Hydrocarbon fuels and oils					
				 
							
					
						MRC:
						The speed of the item required to produce its rated capacity.AHYZ
					 
					
						Operating Speed At Rated Capacity:
					
					
						1800.0 revolutions per minute and 2400.0 revolutions per minute					
				 
							
					
						MRC:
						The position in which the pumping element/s/ is designed to operate.AHZA
					 
					
						Pumping Element Operating Position:
					
					
						Horizontal					
				 
							
					
						MRC:
						The direction in which the pump shaft turns during operation.AHZD
					 
					
						Pump Rotation Direction:
					
					
						Clockwise					
				 
							
					
						MRC:
						The design of a centrifugal pump as determined by the direction of media flow with respect to the axis of the shaft.AHZE
					 
					
						Centrifugal Pump Design:
					
					
						Mixed flow					
				 
							
					
						MRC:
						The number of impellers incorporated in the centrifugal pump.AHZF
					 
					
						Centrifugal Pump Impeller Quantity:
					
					
						1