Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Teilenummer:
ns4aw1316
Entmilitarisierung:
No
Lagerfähigkeit:
Maßeinheit:
NIIN:
002848665
NSN
Nationale Bestandsnummer:
5970-00-284-8665 5970002848665
TXT
Beschreibung:
Standoff Insulator
INC
INC
Artikelname-Code:
00225
MRC:
The application of color or a series of colors for the expressed purpose of identifying the specific functional design and/or the system application of an item.AAPC
Identification Code Color:
White
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
2.000 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
1.000 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
1.000 inches
MRC:
The maximum potential gradient that the insulating material can withstand per mil /0.001 inch/ thickness without rupture.ACGY
Dielectric Material Voltage Rating Per Mil Thickness In Volts:
Not rated
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
2 threaded hole
MRC:
A designation distinguishing one group of screw thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter,and the thread location.CQBP
Screw Thread Series Designator And Location:
Electrical termination unc err-100 err-100
MRC:
A designation distinguishing one group of screw thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter,and the thread location.CQBP
Screw Thread Series Designator And Location:
Mounting facility unc err-100 err-100
MRC:
A designation distinguishing one group of screw thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter,and the thread location.CQBP
Screw Thread Series Designator And Location:
Electrical termination unc
MRC:
A designation distinguishing one group of screw thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter,and the thread location.CQBP
Screw Thread Series Designator And Location:
Mounting facility unc
MRC:
None.CQHX
First Center Distance:
0.500 inches
MRC:
The number of screw threads on the item per linear inch,including incomplete threads,on a line parallel to the thread axis and the thread location.CQTP
Screw Thready Qty Per Inch (tpi) And Location:
20 electrical termination err-100 err-100
MRC:
The number of screw threads on the item per linear inch,including incomplete threads,on a line parallel to the thread axis and the thread location.CQTP
Screw Thready Qty Per Inch (tpi) And Location:
20 mounting facility err-100 err-100
MRC:
The number of screw threads on the item per linear inch,including incomplete threads,on a line parallel to the thread axis and the thread location.CQTP
Screw Thready Qty Per Inch (tpi) And Location:
20 electrical termination
MRC:
The number of screw threads on the item per linear inch,including incomplete threads,on a line parallel to the thread axis and the thread location.CQTP
Screw Thready Qty Per Inch (tpi) And Location:
20 mounting facility
MRC:
The length of a straight line which passes through the center of a coaxial cylinder which would bound the crest of an external thread or the root of an internal thread and terminates at the circumference,and the thread location.CRFL
Screw Thread Diameter And Location:
0.250 electrical termination inches err-100 err-100
MRC:
The length of a straight line which passes through the center of a coaxial cylinder which would bound the crest of an external thread or the root of an internal thread and terminates at the circumference,and the thread location.CRFL
Screw Thread Diameter And Location:
0.250 mounting facility inches err-100 err-100
MRC:
The length of a straight line which passes through the center of a coaxial cylinder which would bound the crest of an external thread or the root of an internal thread and terminates at the circumference,and the thread location.CRFL
Screw Thread Diameter And Location:
0.250 electrical termination inches
MRC:
The length of a straight line which passes through the center of a coaxial cylinder which would bound the crest of an external thread or the root of an internal thread and terminates at the circumference,and the thread location.CRFL
Screw Thread Diameter And Location:
0.250 mounting facility inches
MRC:
A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread and the location.CRPG
Thread Class And Location:
2b electrical termination err-100 err-100
MRC:
A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread and the location.CRPG
Thread Class And Location:
2b mounting facility err-100 err-100
MRC:
A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread and the location.CRPG
Thread Class And Location:
2b mounting facility
MRC:
A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread and the location.CRPG
Thread Class And Location:
2b electrical termination
MRC:
None.CRPR
Second Center Distance:
0.500 inches
MRC:
The element,compound,or mixture of which the item is fabricated,excluding any surface treatment,and its location.MTLC
Material And Location:
insulation, electrical, jan-i-10, grade l-3a
MRC:
The plating,dip,and/or coating that cannot be wiped off. plating and/or coating is any chemical and/or metallic additive,electrochemical,or mild mechanical process which protects the surface of the item and its location.STLC
Surface Treatment And Location:
glazed
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Pillar