Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Informationen zum Teil
On off switch
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Multimeter
MRC:
The type of electrical circuit in which the item is designed to be used.AACT
Circuit Current For Which Designed:
Ac and dc
MRC:
An overall measurement between specified points of an item,in distinction from height.ABFY
Overall Depth:
36.0 millimeters
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
174.0 millimeters
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
90.0 millimeters
MRC:
Indicates the type of device used to register the condition(s).AMKD
Indicator Type:
Digital display
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Bench or hand held
MRC:
The source of power which provides the energy required for the operation of the item.AWZJ
Power Source:
Internal
MRC:
Indicates the type of display provided.BFQN
Display Type:
Liquid crystal
MRC:
The number of digits displayed.BFQP
Display Digit Quantity:
3-1/2
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
-1.999/+1.999 amperes, ac single indicator 1st range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
-1.999/+1.999 amperes, dc single indicator 2nd range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
-1000.0/+1000.0 volts, dc single indicator 13th range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
-19.99/+19.99 milliohms single indicator 8th range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
-199.9/+199.9 kilohms single indicator 3rd range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
-199.9/+199.9 microamperes, ac single indicator 4th range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
-199.9/+199.9 microamperes, dc single indicator 5th range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
-199.9/+199.9 ohms single indicator 11th range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
-199.9/+199.9 milliamperes, ac single indicator 6th range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
-199.9/+199.9 milliamperes, dc single indicator 7th range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
-199.9/+199.9 millivolts, ac single indicator 9th range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
-199.9/+199.9 millivolts, dc single indicator 10th range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
-750.0/+750.0 volts, ac single indicator 12th range
MRC:
The means provided for selecting a scale.BLSB
Scale Selection Method:
Switch
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Internal battery accommodation and portable
MRC:
The means provided for electrical connection to a circuit and the number of each type of connection.CTTD
Circuit Attachment Method And Quantity:
2 probe, direct contact and 2 wire lead
MRC:
The value(s) of root mean square or direct current potential which must be applied to the item for operation,expressed in volts.CTWN
Operating Voltage Rating In Volts:
9.0 dc
MRC:
An indication of the nuclear hardness criticality of the item.NHCF
Nuclear Hardness Critical Feature:
Nonhardened
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Hand-held