Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Safety Relief Valve
MRC:
The part that controls the flow through the item.ADQU
Flow Control Device:
Poppet
MRC:
The maximum temperature at which the item is rated to operate for an extended period of time.AEHZ
Maximum Operating Temp:
-80.0 degrees fahrenheit 1st response400.0 degrees fahrenheit 2nd response
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the connection.AHNC
Connection Style:
G46b plain (pipe) 1st end
MRC:
The means used to control the operation of the valve.AQLR
Valve Operation Method:
Automatic
MRC:
Indicates the type of connection/s/.AWLS
Connection Type:
Threaded external pipe 1st end
MRC:
The maximum pressure at which the item is rated for operation.CQGM
Maximum Operating Pressure:
100.0 pounds per square inch single response
MRC:
A designation that is used for the purpose of general identification of the thread.CQJX
Thread Size:
0.250 inches 1st end
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Aluminum alloy body
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Aluminum alloy flow control device
MRC:
The specification,standard,or manufacturers reference,and the classification designation,such as class,condition,temper,and the like,that identifies the material.MDCL
Material Specification:
Qq-a-225/6 federal specification single material response flow control device
MRC:
The specification,standard,or manufacturers reference,and the classification designation,such as class,condition,temper,and the like,that identifies the material.MDCL
Material Specification:
Qq-a-225/6 federal specification single material response body
MRC:
The type of media for which the item is designed.MEDA
Media For Which Designed:
Air 1st response
MRC:
The type of media for which the item is designed.MEDA
Media For Which Designed:
Carbon dioxide 2nd response
MRC:
The type of media for which the item is designed.MEDA
Media For Which Designed:
Hydrogen 4th response
MRC:
The type of media for which the item is designed.MEDA
Media For Which Designed:
Oxygen, gaseous 5th response
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Err-090
MRC:
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.THSD
Thread Series Designator:
Npt 1st end