Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Pressure Switch
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
2.188 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
3.344 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
1.000 inches
MRC:
A measurement from the bottom to the top of the body,in distinction from depth.ADAU
Body Height:
2.641 inches
MRC:
The general classification of a pressure switch based on the reference method used to measure the sensed pressure.AJZC
Pressure Switch Type:
Gage
MRC:
An indication of whether the initial action of the contacts occurs as the result of an increase or decrease in stimulus.CQGB
Contact Action Stimulus:
Increase
MRC:
The designation that identifies the electrical configuration of a nonpile-up contact group including the number of switching poles or forms.CRLD
Nonpile-up Contact Arrangement:
1 pole, single throw, normally closed, momentary action
MRC:
Indicates the type of terminal for providing electrical connection to the item.CSCF
Terminal Type:
Tab w/screw
MRC:
The amount of current that the contacts are rated to make or break with a specified load.CTHF
Contact Load Current Rating:
16.0 amperes resistive load second voltage
MRC:
The amount of current that the contacts are rated to make or break with a specified load.CTHF
Contact Load Current Rating:
8.0 amperes resistive load first voltage
MRC:
The adjustability of the contact.CTYC
Contact Adjustability:
Deactuation point not adjustable and actuation point not adjustable
MRC:
The rating of the stimulus required to actuate and/or deactuate the contact(s).CTYX
Contact Stimulus Rating:
600.00 actuation point pounds per square inch gage and 400.00 deactuation point pounds per square inch gage
MRC:
The voltage for which the contact(s) is rated at sea level or at a specified altitude,expressed in volts.CTZB
Contact Voltage Rating In Volts:
120.0 ac at sea level second voltage
MRC:
The voltage for which the contact(s) is rated at sea level or at a specified altitude,expressed in volts.CTZB
Contact Voltage Rating In Volts:
240.0 ac at sea level first voltage
MRC:
The type of media for which the item is designed.MEDA
Media For Which Designed:
Gas or liquid
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Rectangular w/bracket