Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
					
					
						Entmilitarisierung:
						Yes - DEMIL/MLI					 
					
					
					
				 
			 
							
					
						Informationen zum Teil
						Open construction without sealed shaft and panel seal;  45 degrees angleof throw;  25, 000 rotational life cycles;  vibration grade 10 to 2, 000 hz frequency range;  shock type medium impact; insulation material glass laminate;  altitude 70, 000 ft;  cocentric shaft;  reference data,  3a2s1,  ti-6820.2,  fa-9996,  vprtav,  vor/dme,  vor eq.,  vol 8,  sec 8,  pg 8-428
					 
				 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Rotary Switch				
			 
			
							
										
					
						MRC:
						A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread.AAJD
					 
					
						Thread Class:
					
					
						2a single mounting facility					
				 
							
					
						MRC:
						A measurement of the extent of threads,including incomplete threads,along a line parallel to the longitudinal axis.AASA
					 
					
						Thread Length:
					
					
						0.375 inches  single mounting facility					
				 
							
					
						MRC:
						The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
					 
					
						Overall Length:
					
					
						1.812 inches 					
				 
							
					
						MRC:
						The distance measured in a straight line from the bottom to the top of an item.ABKW
					 
					
						Overall Height:
					
					
						1.000 inches 					
				 
							
					
						MRC:
						An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
					 
					
						Overall Width:
					
					
						0.937 inches 					
				 
							
					
						MRC:
						A measurement of the longest straight line across a circular cross-sectional plane.ADAV
					 
					
						Overall Diameter:
					
					
						1.000 inches 					
				 
							
					
						MRC:
						The number of individual sections included in the item.AFBH
					 
					
						Individual Section Quantity:
					
					
						2					
				 
							
					
						MRC:
						The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
					 
					
						Operating Tempurature Range:
					
					
						-65.0/+85.0 degrees celsius					
				 
							
					
						MRC:
						The national stock number or the identification information of the end equipment for which the item is a part.AGAV
					 
					
						End Application:
					
					
						2gvortac,  fa-9996/3					
				 
							
					
						MRC:
						The general configuration of the contacts of a switch that describes its basic switching structure.AJZE
					 
					
						Switch Contact Basic Design:
					
					
						Nonpile-up nonsymmetrical					
				 
							
					
						MRC:
						The means of attaching the item.AXGY
					 
					
						Mounting Method:
					
					
						Threaded bushing single mounting facility					
				 
							
					
						MRC:
						A designation that is used for the purpose of general identification of the thread.CQJX
					 
					
						Thread Size:
					
					
						0.375 inches single mounting facility					
				 
							
					
						MRC:
						The voltage for which the contacts are rated,expressed in volts.CQMK
					 
					
						Contact Voltage Rating In Volts:
					
					
						115.0 ac at sea level					
				 
							
					
						MRC:
						The voltage for which the contacts are rated,expressed in volts.CQMK
					 
					
						Contact Voltage Rating In Volts:
					
					
						28.0 dc at sea level					
				 
							
					
						MRC:
						The number of positions to which the switch actuator may be indexed.CRJH
					 
					
						Switch Actuator Indexing Position Quantity:
					
					
						8 single actuator					
				 
							
					
						MRC:
						Indicates the type of terminal for providing electrical connection to the item.CSCF
					 
					
						Terminal Type:
					
					
						Tab,  solder lug					
				 
							
					
						MRC:
						The increments of angular rotation that the switch actuator moves between adjacent index positions.CSLC
					 
					
						Switch Actuator Positioning Increment:
					
					
						45.0 degrees single actuator					
				 
							
					
						MRC:
						The amount of current that the contacts are rated to make or break with a specified load.CTHF
					 
					
						Contact Load Current Rating:
					
					
						100.0 milliamperes resistive load dc at altitude					
				 
							
					
						MRC:
						The amount of current that the contacts are rated to make or break with a specified load.CTHF
					 
					
						Contact Load Current Rating:
					
					
						100.0 milliamperes resistive load ac at sea level					
				 
							
					
						MRC:
						The amount of current that the contacts are rated to make or break with a specified load.CTHF
					 
					
						Contact Load Current Rating:
					
					
						200.0 milliamperes resistive load dc at sea level and 20.0 milliamperes inductive load dc at sea level					
				 
							
					
						MRC:
						The amount of current that the contacts are rated to make or break with a specified load.CTHF
					 
					
						Contact Load Current Rating:
					
					
						50.0 milliamperes resistive load ac at altitude					
				 
							
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
					 
					
						Style Designator:
					
					
						Circular wafer,  bushing mount					
				 
							
					
						MRC:
						A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.THSD
					 
					
						Thread Series Designator:
					
					