Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Glass Dielect Variable Capacitor
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Piston
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
1.328 inches
MRC:
The length of a straight line which passes through the center of a bushing,and terminates at the circumference.ABKH
Bushing Diameter:
0.193 inches
MRC:
A measurement of the longest dimension of a bushing,in distinction from width.ABXD
Bushing Length:
0.281 inches
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
0.922 inches
MRC:
A measurement of the longest straight line across a circular cross-sectional plane.ADAV
Overall Diameter:
0.312 inches
MRC:
The minimum and maximum values of the permissible change in capacitance caused by a change in temperature,in parts per million per degree celsius.AEBF
Tempurature Coefficient Of Capacitance Range In Ppm Per Deg Celsius:
-150.0/+150.0 single section
MRC:
The ratio of capacitive reactance to resistance,expressed at 25 degrees celsius.AECJ
Quality Factor At 25 Deg Celsius:
350.0
MRC:
A designation distinguishing one group of screw thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter on the mounting facility.AKEJ
Mounting Facility Screw Thread Series Designator:
Unf
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Encased
MRC:
The torque required for the adjustment device.AXGR
Adjustment Device Torque:
Between 1.000 inch-ounces and 10.000 inch-ounces
MRC:
The physical configuration of the bushing.AXGS
Bushing Shape:
Round w/flat
MRC:
Direct current resistance between two conductors that are separated by an insulating material,measured at 25 degrees celsius.AXGT
Insulation Dc Resistance At 25 Deg Celsius:
1000.0 gigohms
MRC:
Direct current resistance between two conductors that are separated by an insulating material,measured at the maximum operating temperature of the item.AXGX
Insulation Dc Resistance At Max Operating Temp:
100000.0 megohms
Bushing Width:
0.173 inches
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
1 threaded bushing
MRC:
The temperature/s/ at which an item can function without voltage derating.CQJJ
Nonderated Operating Temp:
Between -55.0 degrees celsius and 125.0 degrees celsius
MRC:
A designation that is used for the purpose of general identification of the thread.CQJX
Thread Size:
0.190 inches
MRC:
The minimum and maximum values of the electrical capacitance measured between two specified points on the item,expressed in picofarads.CTGN
Capacitance Range In Picofarads:
+1.0/+52.0 single section
MRC:
The highest potential and type that may be applied to the item,at the highest operating temperature permissible without voltage derating.CTGP
Nonderated Voltage Rating And Type:
1000.0 dc continuous single section
MRC:
Indicates the type and number of drive(s) provided for the adjustment device.CTGR
Adjustment Device Drive Type And Quantity:
1 slotted screw
MRC:
The drift of capacitance,expressed in picofarads.CTGS
Capacitance Drift In Picofarads:
0.26 single section
MRC:
The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.TEST
Test Data Document:
81349-mil-c-14409 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.).
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
1 turret