Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Informationen zum Teil
Multiple-gas monitor
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Gas Detector
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
4.650 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
1.900 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
3.000 inches
MRC:
Indicates the type of detecting element included.AMRX
Detecting Element Type:
Photo-ionization, catalytic-bead, electrochemical
MRC:
An indication of whether or not the detecting element can be detached from the item.AMRZ
Detecting Element Detachability:
Detachable
MRC:
The value(s) of potential for which the item is rated.AMSE
Voltage Rating:
120.0 pounds per hour wet
MRC:
An indication of whether or not a preamplifier is included.AMSL
Preamplifier:
Not included
MRC:
An indication of whether or not a connector is included.AMSN
Connector:
Included
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
Rechargeable li-ion and alkaline battery packs; 2-line 16 digit lcd; buzzer and flashing red led warning; 20, 000 points datalogging; 2-speed vacuum pump; -20 to +45 degrees c operating temperature; case includes monitor, sensors, batteries, filters, and other accessories
MRC:
Describes the capabilities,intended use,and/or purpose for which the item is provided.FTLD
Functional Description:
Programmable multiple-gas monitor designed to provide continuous exposure monitoring of toxic organic and inorganic gases, oxygen and combustible gases for workers in hazardous environments