Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Circuit Breaker Box
MRC:
An overall measurement between specified points of an item,in distinction from height.ABFY
Overall Depth:
3.250 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
8.375 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
6.125 inches
MRC:
The name and number of those parts furnished with the item of supply that have not been specified elsewhere.ACSY
Furnished Items And Quantity:
2 fuse pullout
MRC:
A designation of the standard mounting facility arrangement provided.AESL
Standard Mounting Pattern Designator:
4 point-rectangular
MRC:
The means of attaching the item.AXGY
Mounting Method:
Unthreaded hole
MRC:
Indicates the type and number of circuit breakers provided.BGJL
Circuit Breaker Type And Quantity:
1 single pole
MRC:
The maximum electrical current which the circuit breaker will carry without interrupting the circuit,expressed in amperes.BGJM
Circuit Breaker Current Rating In Amps:
60.0
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Cover
MRC:
Indicates the type and number of entrances provided.CPLF
Entrance Type And Quantity:
1 rectangular/square
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Aluminum alloy
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Rectangular, flush mounting
MRC:
The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.TEST
Test Data Document:
19207-7044041 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)